Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
62 Cards in this Set
- Front
- Back
Who is responsible for developing an operating instruction to specify tool accountability procedures |
Vehicle fleet manager or vehicle maintenance superintendent |
|
The vehicle maintenance flight material control section point of contact coordinates with applicable supervisors or their designees to update and perform inventories on composite tool kits on all of these occurrences except |
Quarterly |
|
Who ensures tools in precision measurement equipment assigned to composite tool kits are scheduled for calibration and certification |
Vehicle management flight material control section |
|
Type III IV and V hydrant systems will be flushed at least |
Monthly |
|
When performing a hydrant flushing operation ensure the loop is flushed |
With a minimum of twice the line volume |
|
When obtaining quantity readings with the automatic tank Guage tank control unit which key must you press 1st when switching between tanks |
Tanks |
|
Approximately how long will the nitrogen supply last when an automatic tank gauging tank control unit display an alarm indicating the supply has dropped below 200 pounds per square inch |
One month |
|
When performing a periodic cryotainer inspection which items listed in technical order 37C2-8-1-116WC should you complete |
All items proceeded by an asterisk * |
|
What action if any should be taken if a commercial delivery operator does not provide A DD form 250 with a liquid oxygen shipment |
Inform the fuel service centre and await for further guidance |
|
Which of the following cryotainer valves should be in the open position before starting a liquid nitrogen receipt |
Vent valve |
|
When preparing to issue liquid oxygen what action if any should be taken if a review of a receiving tanks AFTO form 134 finds that the forms not properly filled out |
Do not service the receiving tank |
|
Before beginning a liquid oxygen received ensure the commercial delivery operator |
Purges the transfer hose to remove potential contaminants |
|
To what pressure range should source tank pressure be set for cryogenic issuing |
10 to 15 psi |
|
When preparing to issue liquid nitrogen what action if any should you take if a receiving tanks AFTO form 244/245 list an open red X condition |
Do not fill the receiving tank |
|
Which steps should we take in if a liquid oxygen cart fails in odor test |
Perform an odor test on the storage tank that service the cart |
|
Approximally what size sample should be taken for an odor test |
200 milliliter |
|
What symbol should you enter on the AFTO form 244/245 if a routine inspection on a crotainer goes overdue |
Red dash |
|
When documented a cryotainer product issue to a liquid oxygen cart on the AFTO Form 134 what information should be entered in block 4 |
The initials of the individual that filled the cart |
|
When documenting a product issue to liquid oxygen cart on the AFTO Form 134 how should odor test results be annotated in block 2 column D |
Pass or fail in column D |
|
When documenting a cryogenic product receipt on the DLA Form 2046 from which of the following documents is the vendors invoice obtained |
DD Form 250 |
|
How often should hot refuelling personnel undergo certification For hot refuelling operations |
Annually |
|
Who may approve deviations from hot refuelling policies when combat or emergency situations require the use of hot refuelling |
Major command commander MAJCOM |
|
Which aircraft does not require a hot brake check before entering the hot refuelling pad |
F15 |
|
When performing rapid Defueling operations into fuel servicing vehicles the high level shut off now should be tested within the 1st |
Minute of fuel flow |
|
When is a rapid Defuel operation considered a hot defuel |
Whenever the source or provider aircraft has any engine running |
|
Concurrent servicing operations supporting sortie generation operations are not authorised on what aircraft |
B-2 |
|
Who is responsible for on site supervision during all aspects of a concurrent servicing operations supporting combat sortie generation |
Concurrent servicing supervisor |
|
During concurrent servicing of cargo or passenger aircraft the deplaining personnel should not come with in a minimum of how many feet from any aircraft fuel vent outlet |
25 |
|
Who is responsible for controlling and monitoring all concurrent servicing of cargo passenger aircraft operations to include cargo baggage loading unloading maintenance fuel or oxygen servicing and fleet servicing |
Chief servicing supervisor |
|
During in shelter refuelling with the aircraft entry doors close fuel servicing vehicle engines should not be allowed to operate for more than what maximum number of minutes |
20 |
|
Crew members conducting in shelter refuelling with aircraft entry doors close should be limited to what maximum number of operations for duty day |
4 |
|
During multiple source refuelling what action if any should be taken if backflow is detected |
Stopped operation immediately |
|
When multiple source refuelling if multiple refuelling units are located on the same side or wing of an aircraft each vehicle |
Must remain position and bonded until fuel flow is terminated on all trucks on that side of the aircraft |
|
When configuring an automatic point of sale device user interface terminal what tab allows you to enter information about the fields management flight to which the equipment is assigned |
Base |
|
When configuring an automated point of sale device truck interface module what setting screen allows you to add and edit information regarding the fueling unit to which the TIM is assigned |
Fuel piont configuration |
|
While performing expeditor duties what action must you take if you notice an unsafe feeling operation |
Immediately terminate the operation |
|
Which of the following operation requires a fuel expediter be used |
Aircraft fueling |
|
Each R20 multi aircraft platform is equipped with how many feet of communication wire |
1500 |
|
What type of hose should be used on the discharge side of the R18 for transfer operations |
Six inch hard hose |
|
How many fillstand assemblies are included in the fuels operational readiness capability equipment system |
2 |
|
At a minimum how often should the R18 pumping unit oil filter be changed |
Every 500 hours of operation or semi annually whichever comes 1st |
|
What is the proper tire pressure setting for the R18 pumping unit |
75 psi |
|
How often should the sump tank on the R19 filled separator unit be drained |
Daily |
|
Which condition does not require replacement of filter elements on the R19 filter separator unit |
Reading of 16PSID on the differential pressure Gauge |
|
What pressure should the surge suppressor Gauge on the R20 servicing unit indicate when the feeling system is not operating |
90 psi |
|
The Micronic filter elements on the R20 Servicing unit should be replaced when the differential pressure readings exceed |
15PSID |
|
When setting up the communication panel on an R18 will action should you take 1st |
Turn off the panel power switch |
|
When performing off load operations with the fields operational readiness capability equipment system the Deadman switch on the communications panel of the R18 pumping unit should be placed in what position |
No dead man |
|
When performing transfer operations with an R18 pumping unit what reading should the oil pressure Gauge indicate if the unit is not operating properly |
50 ± 10 psi |
|
When performing fuel servicing operations within R18 pumping unit the throttle control should manually reset to what revolution per minute setting |
2250 |
|
When performing fuel servicing operations with an R20 Servicing platform in what position should the manual remote control switch on the |
Remote |
|
When preparing an R18 with shipment dispose of all drain fuel in accordance with |
Local and federal environmental regulations |
|
When reconstituting fuels operational readiness capability equipment all rolling stock should be drained in accordance with |
Local transportation guidelines |
|
What is the simplest and most expedient method of fuel resupply when operating from a host nation airfield |
The same source of supply used by the host airfield |
|
What organisation normally provides management of overland petroleum support including inland waterways to us land based forces of all department of defence components |
US Army |
|
What is the maximum number of gallons in area bulk fuel delivery system carries per sortie |
30000 |
|
What are organization is responsible for the procurement of fuel at deployed locations |
Defence logistics agency energy (DLA) |
|
When selecting a site for bladder operations aside should have less than what degree of slope |
3゚ |
|
When performing fuels mobility site planning what organisation should be your 1st source of information for infrastructure availability |
Responsible major command MAJCOM |
|
With which of the following altering field should special precautions be taken due to its high volatility |
Jet B |
|
What component of a unit type code defines the basic mission the utc Is capable of accomplishing |
Mission capabilities statement MISCAP |
|
What software database is used to identify a unit type codes ability to perform its mission capabilities statement and identify Shortages |
AEF reporting tool (ART) |