• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/27

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

27 Cards in this Set

  • Front
  • Back

What valve acts as a safety first valve to prevent a backflow of steam?

Stop and check valve

On a watertube boiler, the feedwater line is installed in the steam drum at:

Slightly below the NOWL

The water level in the boiler is controlled by a :

Continuity probe

The max size of a blowoff line is:

2 1/2"

The min size for a water column connection from the boiler is:

1"

The item or trim that does not require a pressure gauge is the:

Gauge glass

Safety valves shall be located on the:

Reheaters

On a firetube boiler, the burner section is located in the:

Furnace

A retractable sootblower on a watertube boiler is found at:

Furnace area

Which 2 codes are addressed when connecting test flanges?

ASME section 1


B 31.1

What is the minimum size of the boiler feedwater line for a boiler over 100ft²?

3/4"

What is the difference between a safety valve and a safety relief valve?

A safety valve is used on the vapor system space (steam) and a safety relief valve is used on the liquid system space (water)

What is the min and max graduation on a pressure gauge for a 100psig power boiler?

Min 0 - 150psig


Max 0 - 200psig

Water columns designed for a 300psig steam boiler will be made of what materials?

Ductile iron or steel

What are the 3 main steps to troubleshooting?

Diagnosis of symptoms


Probable cause of malfunction


Corrective action

What grade does a steam main have?

1" over 20'

Boilers having over 500ft² of water heating service must have how many means of feeding water?

2

What is the minimum size for blowoff piping?

1" for 100 ft²


3/4" for less than 100 ft²

What is the max size for blowoff piping?

2.5"

What is the minimum size drain piping for high temp water boilers?

1"

What is the min size piping for a water column?

1"

What are the 4 areas of boiler teim for a firetube boiler?

Furnace side


Products of combustion


Water side


Steam side

What is considered the first pass of the boiler?

The furnace

What is breeching?

When all the products of combustion are allowed outside the boiler and become flue gas

What trim is associated with the furnace area?

Fuel valve


Burner assembly


Air control dampers


Intake assemblies

What trim is included in the water side area?

Full length shell


The furnace


Fire tubes


NOWL

What is the min size for blowdown piping?

3/4"