• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/38

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

38 Cards in this Set

  • Front
  • Back

Fixed your calculations

To determine the occupant load of each sex the total occupant load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios of each fixture time shall be applied to the occupant load of each sex. Any total calculations should always round up to the next whole number

Single user toilet facilities in bathing room fixtures

The plumbing fixture is located in a single user toilet facility and bathing rooms, include family or assisted toilet and bathing rooms that are required from the international building code. They shall be identified for use by either sex

Lavatory distribution

Where two or more toilet rooms are provided for each sex, The required number of lavatory shall be distributed proportionately to the required number of water closets

Separate facilities

Where plumbing fixtures are required, separate facilities shall be provided for each sex

Prohibited toilet room location

Toilet rooms shall not open directly into a room used for preparation of food services to the public

Location of toilet facilities in occupancies other than malls

The required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet

Accessible plumbing facilities


(Exposed pipes and surfaces)

Water supply and drain pipes under accessible Lavatory and sinks shall be covered or otherwise configured to protect against contact. Pipe covering shower comply with same a112.18.9

Water supplied protection

The supply lines and fittings for every plumbing fixture shall be installed so as to prevent backflow

Water supplied protection

The supply lines and fittings for every plumbing fixture shall be installed so as to prevent backflow

Installation


Water closets,urinals,lavatories and bidets.

Water closets, urinal, lavatory or bidets shall not be less than 15 inches from center to any side wall or a partition.

If partitions or obstructions are not separating fixtures, they shall not be set closer than ——inches center to center between adjacent fixtures. What is the minimum clearance in front of these fixtures——?


Water closets urinals Lavatories and bidets

30” inches


21”inches

Water closet compartments shall not be less than—- inches in width and not less than—- in depth from floor mounted water closet

30” width


60” inches in depth

Water closet compartments


(Wall hung toilets)

30 inches in width


56 inches in depth

Urinal partitions


The horizontal dimensions between walls or partitions at each urinal shall not be less than—-inchesThe walls or partitions she will not begin at a light no greaterInches and not extend less then—-inches above the finished floor surface

30 inches,


12”


60”

Urinal partition


The walls or partitions shall not extend from the wall surface at each side of the urinal not less than—- inc or to a point not less than—- inc Beyond the outer most front lip of the urinal measured from the finished back wall surface which ever is greater

18”


6”

Designed of overflows

Where any fixture is provided with an overflow, the waist shall be designed and installed so the standing water in the fixture will not rise in the overflow when the stopper is closed, and water will not remain in the overflow when the fixture is empty

Automatic clothes washer


(water connection)

The water supply to an automatic clothes washer shall be protected against backflow buy an air gap that is integral with the machine or backflow preventer shall be installed

Bidets

The discharge water temperature from a bidet fitting shall be limited to not greater than 110°F find a water temperature limiting device. Should also be protected by backflow by an air gap or backflow preventer

Drinking fountain

Shall not be required for an occupant load of 15 or fewer

High and low drinking fountains

Where drinking fountains are required, not fewer than two drinking fountains shall be provided one drinking fountain shall comply with the requirements for people who use wheelchairs and one drinking fountain shall comply with the requirements for standing persons

Children drinking fountains. What is the minimum height above the floor for the spout??

30” inches

Individual shower valves Shall be —— And have the means to limit the maximum setting of the valve to —— degrees Fahrenheit which shall be sealed adjusted in accordance with manufacturers instructions

Pressure balanced, thermostatic


120 degrees Fahrenheit

Head shampoo sink faucet shower have a water limited to —- degrees Fahrenheit. They should also have——-to prevent cross overflow between the hot and cold water supply connection

120 degrees Fahrenheit


Integral check valves

All floor drains should have—— to be cleaned

Ready access

All floor drains shall have —-strainers floor and trench drains Shall have a drain not less then ——“ unless it’s one or two family dwelling . Which then the can no less then ——“

Removable, 3 inches, 2 inches,

Flushing devices require. Water closet,urinal, clinical sink.plumbing fixture that depends on trap siphonage to discharge

Provide with a flushometer valve, flushometer tank or flush tank

Domestic food waste disposer shall not be connected to a dream less than——“ in diameter

1 1/2”

Commercial food disposer what is the minimum train size—— inDiameter. Shall also be connected and trapped ——-from any other fixture or sink compartment

1 1/2”


Separately

Lavatories


Group wash up equipment shall conform to the requirements of every—— inches of room space shall be considered one lavatory

20” inches

Shower waste outlets. Waste outlet serving shower so not be less than——“ inches or have a removable strainer not less than—-“ inches with a strainer opening not less than——“ inches

1 1/2”. 3”. 1/4”

Shower dimensions (exceptions) having less than——“ in minimum dimensions measured from the finish interior dimensions of the compartment. It shall have not less than—- cross sectional area

25”. 1,300

Floor and wall area. War materials shall not extend to a height of not less than—-‘ feet above the room floor level, and not less thaninches above the drain of the tub or shower. All walls and materials shall be watertight

6 feet. 70”

Shower access shall be unobstructed and have a width of not less than—-“

22”

Shower line shall turn up on all sides not less than—-inches above the finished threshold level. Liners shall not be fastened at any point Less then —-“ above the finish threshold. Shall not be pitched less than—-% slope

2”. 1”. 2%

Urinals. Substitutions for water closets

She’ll not be substituted for more than 67% of the required water closet in assembly and educational occupancy‘s. Urinals shall not be substituted for more than 50% of the required water closets in all other occupancy’s

Water closets

A 4“ x 3“ closet bend shall be acceptable. Where a 3 inch band is utilized on water closets, a 4“ x 3“ flange shall be installed to received the fixture horn

Whirlpools bathtubs. (Installation)

The pump shall be located above that weir of the fixture trap

Whirlpool bathtubs (access to pump) pump access should be not less than—-x—-“ for pump where the pumps are located 2 feet from excess opening .—-x—- access panel should be installed

12x12”. 18x18”