Fixed your calculations |
To determine the occupant load of each sex the total occupant load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios of each fixture time shall be applied to the occupant load of each sex. Any total calculations should always round up to the next whole number |
|
Single user toilet facilities in bathing room fixtures |
The plumbing fixture is located in a single user toilet facility and bathing rooms, include family or assisted toilet and bathing rooms that are required from the international building code. They shall be identified for use by either sex |
|
Lavatory distribution |
Where two or more toilet rooms are provided for each sex, The required number of lavatory shall be distributed proportionately to the required number of water closets |
|
Separate facilities |
Where plumbing fixtures are required, separate facilities shall be provided for each sex |
|
Prohibited toilet room location |
Toilet rooms shall not open directly into a room used for preparation of food services to the public |
|
Location of toilet facilities in occupancies other than malls |
The required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet |
|
Accessible plumbing facilities (Exposed pipes and surfaces) |
Water supply and drain pipes under accessible Lavatory and sinks shall be covered or otherwise configured to protect against contact. Pipe covering shower comply with same a112.18.9 |
|
Water supplied protection |
The supply lines and fittings for every plumbing fixture shall be installed so as to prevent backflow |
|
Water supplied protection |
The supply lines and fittings for every plumbing fixture shall be installed so as to prevent backflow |
|
Installation Water closets,urinals,lavatories and bidets. |
Water closets, urinal, lavatory or bidets shall not be less than 15 inches from center to any side wall or a partition. |
|
If partitions or obstructions are not separating fixtures, they shall not be set closer than ——inches center to center between adjacent fixtures. What is the minimum clearance in front of these fixtures——? Water closets urinals Lavatories and bidets |
30” inches 21”inches |
|
Water closet compartments shall not be less than—- inches in width and not less than—- in depth from floor mounted water closet |
30” width 60” inches in depth |
|
Water closet compartments (Wall hung toilets) |
30 inches in width 56 inches in depth |
|
Urinal partitions The horizontal dimensions between walls or partitions at each urinal shall not be less than—-inchesThe walls or partitions she will not begin at a light no greater— Inches and not extend less then—-inches above the finished floor surface |
30 inches, 12” 60” |
|
Urinal partition The walls or partitions shall not extend from the wall surface at each side of the urinal not less than—- inc or to a point not less than—- inc Beyond the outer most front lip of the urinal measured from the finished back wall surface which ever is greater |
18” 6” |
|
Designed of overflows |
Where any fixture is provided with an overflow, the waist shall be designed and installed so the standing water in the fixture will not rise in the overflow when the stopper is closed, and water will not remain in the overflow when the fixture is empty |
|
Automatic clothes washer (water connection) |
The water supply to an automatic clothes washer shall be protected against backflow buy an air gap that is integral with the machine or backflow preventer shall be installed |
|
Bidets |
The discharge water temperature from a bidet fitting shall be limited to not greater than 110°F find a water temperature limiting device. Should also be protected by backflow by an air gap or backflow preventer |
|
Drinking fountain |
Shall not be required for an occupant load of 15 or fewer |
|
High and low drinking fountains |
Where drinking fountains are required, not fewer than two drinking fountains shall be provided one drinking fountain shall comply with the requirements for people who use wheelchairs and one drinking fountain shall comply with the requirements for standing persons |
|
Children drinking fountains. What is the minimum height above the floor for the spout?? |
30” inches |
|
Individual shower valves Shall be —— And have the means to limit the maximum setting of the valve to —— degrees Fahrenheit which shall be sealed adjusted in accordance with manufacturers instructions |
Pressure balanced, thermostatic 120 degrees Fahrenheit |
|
Head shampoo sink faucet shower have a water limited to —- degrees Fahrenheit. They should also have——-to prevent cross overflow between the hot and cold water supply connection |
120 degrees Fahrenheit Integral check valves |
|
All floor drains should have—— to be cleaned |
Ready access |
|
All floor drains shall have —-strainers floor and trench drains Shall have a drain not less then ——“ unless it’s one or two family dwelling . Which then the can no less then ——“ |
Removable, 3 inches, 2 inches, |
|
Flushing devices require. Water closet,urinal, clinical sink.plumbing fixture that depends on trap siphonage to discharge |
Provide with a flushometer valve, flushometer tank or flush tank |
|
Domestic food waste disposer shall not be connected to a dream less than——“ in diameter |
1 1/2” |
|
Commercial food disposer what is the minimum train size—— inDiameter. Shall also be connected and trapped ——-from any other fixture or sink compartment |
1 1/2” Separately |
|
Lavatories Group wash up equipment shall conform to the requirements of every—— inches of room space shall be considered one lavatory |
20” inches |
|
Shower waste outlets. Waste outlet serving shower so not be less than——“ inches or have a removable strainer not less than—-“ inches with a strainer opening not less than——“ inches |
1 1/2”. 3”. 1/4” |
|
Shower dimensions (exceptions) having less than——“ in minimum dimensions measured from the finish interior dimensions of the compartment. It shall have not less than—- cross sectional area |
25”. 1,300 |
|
Floor and wall area. War materials shall not extend to a height of not less than—-‘ feet above the room floor level, and not less than—inches above the drain of the tub or shower. All walls and materials shall be watertight |
6 feet. 70” |
|
Shower access shall be unobstructed and have a width of not less than—-“ |
22” |
|
Shower line shall turn up on all sides not less than—-inches above the finished threshold level. Liners shall not be fastened at any point Less then —-“ above the finish threshold. Shall not be pitched less than—-% slope |
2”. 1”. 2% |
|
Urinals. Substitutions for water closets |
She’ll not be substituted for more than 67% of the required water closet in assembly and educational occupancy‘s. Urinals shall not be substituted for more than 50% of the required water closets in all other occupancy’s |
|
Water closets |
A 4“ x 3“ closet bend shall be acceptable. Where a 3 inch band is utilized on water closets, a 4“ x 3“ flange shall be installed to received the fixture horn |
|
Whirlpools bathtubs. (Installation) |
The pump shall be located above that weir of the fixture trap |
|
Whirlpool bathtubs (access to pump) pump access should be not less than—-x—-“ for pump where the pumps are located 2 feet from excess opening .—-x—- access panel should be installed |
12x12”. 18x18” |