Every water supply to a urinal shall be protected by an approved |
Vacuum breaker |
|
Let shower pan material shall weigh blank per foot copper pans Shall be blank gauge |
Lead pan for lbs per foot copper pans 24 gauge |
|
Plumbing fixtures shall be installed in a manner to afford easy access for |
Repair and cleaning |
|
commercial water closets shall be a minimum of blank inches Center to center from each other commercial water closets shall be blank inches from a side wall or partition commercial water closets shall have blank inches of clear space in front of them |
30 inch Center to center 15in from sidewall and 24 in clearance in front |
|
urinal shall be a minimum of blank in Center to center from each other urinal shall have blank inches of clearance from any side wall or partition |
24 inch Center to Center and 12in from side wall or partition |
|
water closets for public use shall be of blank type in Nursery schools or other similar places where Plumbing fixtures are provided for children under blank years old water closets shall be suitable for children's use |
Elongated type and children under 6 years old |
|
Offset eccentric or reducing floor flanges shall not be used for what type of water closet |
Floor mount back Outlet |
|
nonmetallic showers sub pans or Linings may be built up on the job site of not less than blank layers of standard grade blank pound asphalt impregnated roofing felt |
Three layers of 15 pound asphalt impregnated roofing felt |
|
A bathtub shall be limited to blank degrees Fahrenheit |
120 degrees |
|
lighting materials for a shower receptor shall extend upwards on the rough jams of the shower opening to a point no less than blank inches above the top of the finished damn or threshold |
4 inches |
|
Name a gasket material approved for wall mount water closets |
Neoprene |
|
Water closet with flush tank shall be provided with overflows which discharge |
Into the water closet |
|
Where a fixture comes in contact with the wall or floor The Joint between the fixture and the wall or floor shall be made |
Watertight |
|
restaurant kitchen and other special use sinks may be made of approved type bonderized and galvanized sheet metal steel of not less than blank gauge |
16 gauge sheet metal |
|
Wall-hung fixtures shall be rigidly supported by blank supporting members so that no strain is transmitted to the connections |
Metal |
|
The pump and circulation piping for a Whirlpool Bathtub shall be blank to minimize water retention |
Self-draining |
|
Water closet seats shall be properly blank for the water closet Bowl type |
Size d |
|
P a floor drain shall be installed in a toilet room with two or more |
Water closets |
|
Floors shall be blank to floor drains where drainage occurs on a regular or frequent basis |
Sloped |
|
For Ada info and requirements we use the reference standards found in chapter blank of this code |
Chapter 17 referenced standards |
|
Wall mounted water closets shall be securely bolted to an approved |
Carrier fitting |
|
Non water urinal shall have a barrier liquid sealant true or false |
True |
|
a dishwasher drain may be connected to a sink tailpiece as long as it's on the discharge side of the food waste disposal true or false |
False |
|
gutters in public or gang showers shall have their drains space not more than 16 ft from the side walls nor more than 8 feet apart |
False it's the other way around |
|
showers and tub shower shall be provided with individual control valves of the pressure balance or thermostatic mixing valve type true or false |
True |
|
A water heater is a suitable control for maximum hot water temperature in a public gang shower true or false |
False |
|
The access panel for a Whirlpool tub pump must be a minimum of 18 in square true or false |
False it needs to be big enough to get the pump out |
|
water supplies for Lily Pons shall be submitted for approval by The Authority having jurisdiction prior to installation true or false |
True |
|
Shower compartments shall be capable of encompassing a 30-inch Circle true or false |
True 30-inch minimum |
|
the minimum area and dimensions for shower shall be maintained to a point 70 in above the threshold of the Damned true or false |
False it's 70 in from the above the shower drain Outlet |
|
lighting for shower pans shall not be perforated at any point which may be less than one inch above the dam or threshold true or false |
True |
|
A wet room shall be no less than 4ft by 4ft and slope no less than 2% towards the drain true or false |
True |
|
Sixers having concealed slip joint connections shall be provided with an access panel or utility space at least blank inches in diameter |
12 in |
|
Every water supply to a urinal shall be protected by an approved blank |
Vacuum breaker |
|
it's shower receptor shall be of an approved type and be so constructed as to have a minimum Dan or threshold not less than blank or exceeding blank inches |
Not less than 1 inch or exceeding 9 in |
|
What chapter is a reference for a ada fixtures |
Chapter 17 |
|
lead in Copper sub pans or Linings shall be insulated from all conducted substances other than their connecting drain by |
Three layers minimum of 15 lb asphalt felt or equivalent |
|
What kind of fittings may be used in exposed locations in fixture waste on the outlet side of a trap |
Slip joint |
|
what type of fittings must be used in all continuous waste connecting to or receiving the discharge from food waste disposal units |
And approved why or directional fitting |
|
The circulation pump of a whirlpool tub must be above |
The crown weir if the trap |
|
Sent her to any sidewall front to any obstruction Center to center of any water closet |
15 in to any sidewall 24 in free from obstruction 30 inch Center to center from other water closets |
|
From Center to any side wall from another urinal Center to Center |
12in from any side wall and 24 inch Center to Center |
|
Source of public shower room shall have a blank surface |
Non-skid |
|
Strainer serving shower drain shall have a Waterway equivalent to |
At least equivalent to the area of the tailpiece |
|
Water flow rates for water closets urinals emergency safety shower heads and faucets water closet flushometer and lacs residential |
Water closet 1.28 gallons per flush urinals 1 gallon per flush emergency shower heads 1 gallon per minute meter faucet .25 gallons per operation water closet flushometer 1.6 gallons per flush lavatories 2.2 gallons per minute |
|
Commercial water flow regulations water closets Cyrano's emergency safety shower heads metered faucets water closets and lavatories commercial |
Water closets 1.6 gallons per flush urinals 1 gallon per flush metered faucets .25 water closet flushometer 1.6 lavatories .25 |
|
When is a floor drain required in a toilet room according to code |
When there are two water closets or a combo of a urine and a water closet except in a dwelling unit |
|
I weep holes in a shower sub pan drain must be protected from |
Clogging |
|
restaurant kitchen and other special you think may be made of approve Bond rice or galvanized steel of not less than blank gauge |
16 gauge ponderize and galvanized sheet steel |
|
Name four types of water closets that are prohibited |
Invisible seal unventilated space walls which are not thoroughly washed at discharge mypurmist siphonage or the contents of the bowl back into the tank |
|
I flush tank shall have a provision to automatically Supply water to the fixture so as to refill |
the tank after each discharge and to completely shut off the water flow to the tank where the tank is filled to operational capacity |
|
A seamless drawn brass tailpiece shall be blank or blank and not less than blank gauge |
Exposed or accessible and 20 gauge |
|
In an airport restroom what kind of lavatory faucet is required |
Self closing or a metered faucet |
|
If a floor drain is provided in a toilet room what must be done to the floor |
It must be slow towards the drain dummy |
|
What is the minimum clear floor space in front of a lavatory |
P 24 in |
|
Minimum unobstructed shower door opening is |
22 in |