Rule 1

General Provisions

Purpose of the Code

The National Building Code shall provide a framework of minimum standards and requirements for all buildings to regulate their location, design, quality of materials, construction, and use.

Scope of application of NBC

The National Building Code (NBC) applies to the design, location, siting, construction, alteration, repair, conversion, use, occupancy, maintenance, moving, demolition of and addition to public and private buildings, except traditional dwellings and BP 220 projects.

Construction

All on-site work done from site preparation, excavation, foundation, assembly of all the components and installation of utilities and equipment of buildings/structure.

Addition

Any new construction which increases the height or area of an existing building/structure

Alteration

Construction in a building/ structure involving changes in the materials used, partitioning, location/ size of openings, structural parts, existing utilities and equipment but does not increase the overall area thereof.

Renovation

Any physical change made on a building/structure to increase its value, utility and/or to improve its aesthetic quality

Conversion

A change in the use or occupancy of a building/ structure or any portion there of which has different requirements.

Repair

Remedial work done on any damaged or deteriorated portion/s of a building/structure to restore its original condition.

Demolition

The systematic dismantling or destruction of a building/ structure, in whole or in part

Ancillary building structure

A secondary building/ structure located within the same premises, the use of which is incidental to that of the main building/structure

Rule 2

Administration and Enforcement

Duties of Secretary of the DPWH

Policy making, Memorandum circulars, Prescribe fees, Appoint building officials in all municipalities

Building Official

The ______________ is Tasked with the enforcement of the Code in his jurisdiction,Issues, denies, suspends and revokes permits,Undertakes inspection of buildings,Acts on claims



The DPWH Secretary

prescribes the fees

The Building Official

collects the fees

Fee exemptions

Public buildings,Traditional family dwellings that does not exceed 15,000 peso

Options for dangerous buildings

repair, vacation and demolition

Rule 3

Permits

Building Permit

A written authorization granted by the Building Official to an applicant allowing him to proceed with construction after plans, specifications and other pertinent documents have been found to be in conformity with the Code

When is a building permit required?

Before constructing, altering, repairing,converting, moving, adding to,demolishing a building.

Building permit exemptions

Minor constructions/Repair works

Minor construction (exception of fee)

Minor structures 6 sqm or less detached from other buildings, for private use only. (Example: Sheds, poultry houses, greenhouses)

Minor construction (exception of fee)

Open terraces or patios not exceeding 20sqm. or Window grilles

Minor construction (exception of fee)

Garden pools 500mm deep or shallower or Garden masonry walls not exceeding 1.20m in height

Repairs (exception of fee)

Not involving structural members or Of non-load bearing partition walls

Repairs (exception of fee)

Not involving addition or alteration or repairs Of doors, windows, floors, fences and walls or Of plumbing fixtures

If lot is owned, what are the requirements for a building permit

OCT or TCT Tax declaration Current real property tax receipt

If lot is NOT owned,what are the requirements for a building permit

Contract of Lease or Deed of Absolute Sale in place of TCT

No. of set of plans and specs for Permit requirements

Five sets of plans and specs, signed and sealed by various professionals

Issuance of permits

15 days from payment of fees

Liability clause

Article 1723 of the Civil Code

Article 1723 of the Civil Code

states that the engineer or architect who drew up the plans and specs is liable for 15 years from completion of the building should it collapse due to defects in the plans or the ground

Contractor, Construction Supervisor

In case the building collapses due to defects in construction or the use of inferior materials the _______________alongwith the __________________ shall be liable.

Certificate of occupancy Requirements

Certificate of completion, Logbook, As-built plans and specs , Building inspection sheet.

Non-issuance, Suspension,Revocation

Errors in plans and specs, Incorrect or inaccurate data declared, Non-compliance with the Code

RULE 4

Types of Construction

Type I

Wood Construction

Type II

Wood construction with fire-resistant materials with One-hour fire-resistive throughout

Type III

Masonry and wood construction with One hour fire resistive throughout and Incombustible exterior walls

Type IV

Steel, iron, concrete, or masonry construction with Incombustible interiors (ceilings, walls)

Type V

Four-hour fire resistive throughout with Structural elements of steel, iron, concrete or masonry

RULE 5

Fire Zones

Fire zone

Areas within which only certain types of construction are allowed, based on their occupancy, type of construction, and resistance to fire.

Non-fire restricted zones

All types of construction allowed.

Fire restrictive zones

Type I construction NOT allowed.

Highly fire restrictive zones

Types I, II, and III NOT allowed.

more than 1/3 of its total floor area

Buildings in multiple fire zones Shall be considered as part of the more restrictive zone if_______________is in that zone.

Fire resistive rating

The degree to which a material can withstand fire Usually expressed in the form of a time period rating (how long a material can withstand being burned).

RULE 7

Occupancies + Requirements

buildings,lands

Occupancies are assigned to

lands

zones are assigned.

Occupancy classification A

Residential dwellings

Occupancy classification B

Residentials, hotels, apartments

Occupancy classification C

Education and recreation

Occupancy classification D

Institutional

Occupancy classification E

Business and mercantile

Occupancy classification F

Industrial

Occupancy classification G

Storage and hazardous

Occupancy classification H

Assembly other than Group I

Occupancy classification I

Assembly with 1,000 or more occupant load.

Occupancy Classification J

Accessory

Residential

Zoning classification- R

Commercial

Zoning classification- C

General institutional

Zoning classification- GI

Industrial

Zoning classification- I

Utilities, Transportation, Services

Zoning classification- UTS

Special

Zoning classification- SPE

Park structures, Recreation, Entertainment

Zoning classification- PRE

Cultural

Zoning classification- CUL

Agricultural

Zoning classification- A

Agroindustrial

Zoning classification- AI

Planned Unit Development

Zoning classification- PUD

R1

Low-density residential zone,Characterized by single-family and single detached dwellings.

R2

Medium-density residential zone,Characterized by low-rise single-attached, duplex, or multilevel buildings for use as multiple family dwellings.

Basic R2

Single attached or duplex, 1-3 floors.

Maximum R2

Low-rise multi-level building, 3-5 floors.

R3

High-density residential zone, Characterized low-rise or medium-rise buildings for use as multiple family dwellings, Includes low-rise or medium-rise condominium buildings

Basic R3

Rowhouses 1-3 storeys high.

Maximum R3

Medium-rise multilevel structure 6-12 storeys high.

R4

Medium to high-density residential zone,Characterized by low-rise townhouses or buildings for use as multiple family dwellings,Refers to structures on an individual lot ("townhouse")

R5

Very high density residential zone,Characterized by medium-rise to high-rise condominiums.

750mm

Eaves over required windows shall at least be ___________ from the side and rear property lines.

Four-hour fire resistive

Separation 4 hours and Openings, Not allowed.

Firewalls

A fireproof barrier used to prevent the spread of fire between or through buildings.

Allowable firewalls for R1

Not allowed

Allowable firewalls R2

One side only and Maximum 80% of the length of side property line.

Allowable firewalls R3 A

Two sides Maximum 85% of each side,Total should not exceed 65% of lot perimeter and Two storeys high only.

Allowable firewalls R3 B

One side + Rear 90% of side or rear (up to 100% for rear if only 4m),Total should not exceed 50% of lot perimeter,Two storeys high for side, 3.20m high for rear

Allowable firewalls R4

Two sides, Maximum 85% of each side- Total should not exceed 50% of lot perimeter, Maximum height: three storeys

Allowable firewalls R5 Option A

Two sides,Maximum 75% of each side,Total should not exceed 50% of lot perimeter,Maximum height: 8 storeys

Allowable firewalls R5 Option B

One side + Rear,Maximum 65% of side and 50% of rear,Total should not exceed 60% of lot perimeter,Maximum height: 8 storeys for side, 14m for rear.

Total gross floor area

TGFA

TGFA

The total floor space inside the building Includes services/parking (unlike GFA).

BHL

Building height limit

2.50m x 5.00m

Perpendicular parking

2.15m x 6.00m

Parallel parking

3.00m x 9.00m

Jeepney

3.60m x 12.00m

Standard truck/bus

3.60m x 18.00m

Articulated truck

Parking Requirements Hotels -Highly Urbanized

1 slot for every 3 rooms

Parking Requirements Hotels

1 slot for every 7 rooms

Tourist Bus Parking Requirements Hotels

2 parking slots

Articulated Truck Parking Requirements Hotels

1 loading slot

Parking Requirements Churches

for every 50sqm:1 car slot, 1 jeepny slot

Public Universities Parking Requirements

1 car slot for every 5 classrooms

Public Hospital Parking Requirements

1 car slot for every 25 beds1 loading space for 2 jeepney/shuttle slots1 slot for articulated truck

Off-site parking lots

If a multi-floor parking garage is located within a 200-meter radius of the building.

50m apart

The building ingress and the intersection shall be at least

250mm

thickness of foundation

600m

depth of foundation below the surface of the ground

200kg/sqm

Structural loads for First floor live load

150kg/sqm

Structural loads for Second floor live load

120kg/sqm

Structural loads for Wind load for roofs

750mm

Minimum width of stairs

200mm

Maximum riser

200mm

Minimum tread

TLA

PSO + TOSL

TOSL

USA + ISA

MACA

PSO + ISA

TLA

MACA + USA

PSO

AMBF / TLA

GFA

TLA x FLAR

TGFA

GFA X convertor

RULE 8

Light + Ventilation

Inside lot

20% opens space

Interior lot

50% opens space

Corner lot

10% opens space

Corner through lot

5% opens space

Corner through lot abutting 3 or more streets

5% opens space

End lot

30-50% open space

Yard

the required open space left between the outermost face of the building and the property lines

Setback

the width of the yard

4.50,,2.00,,2.00

setbacks for R1

3.00,,2.00,,2.00

setbacks for R2 basic

8.00,,2.00,,2.00

setbacks for R2 max

0.30m

rear and side incremental set backs starting at the send floor

2.00m

Minimum dimension of courts

1.20m wide

All inner courts shall be connected to a street or yard by a passageway at least

6.00sqm

Minimum area for human habitation

2.00m

Min. dimension for human habitation

3.00sqm

Minimum area for Kitchen

1.50m

Min. dimension for kitchen

1.20sqm

Minimum area for Toilet and bath

0.90m

Min. dimension for Toilet and bath

14.00 cubic meters

Air space requirements Habitable rooms

12.00 cubic meters

Air space requirements Workshop,factories, offices

3.00 cubic meters

School rooms

10% of floor area

Minimum area of windows for Habitable room

5% of floor area

Minimum area of windows for Bathrooms, laundry rooms

2.40m;;;300mm

National roads or public highways:footings located at least________ below grad may project ______ (maximum) beyond the property line

500mm ;; 600mm

Foundations may encroach_______into the sidewalk if top of foundation is at least _______ below grade

3.00m

Clearance between sidewalk grade and lowest portion of balcony

3.00m

Arcades shall be at least ______ above the sidewalk grade.

4.00m wide

The chaflan shall be at least

1.00m min. height

Provide railings for walkways located beside the road or an excavation should be at-least

2.40m

Fences shall entirely enclose a construction site with a Minimum height:

2.40m above the walkway

For canopies: clear unobstructed height of

28.00 sqm/person

Occupant load for dwellings

18.60sqm/person

Occupant load for Hotels, apartments

1.80sqm/person

Occupant load for Classrooms

4.60sqm/person

Occupant load for School shops/labs

8.4sqm/person

Occupant load for Hospitals

2.80sqm/person

Occupant load for stores( basement -ground floor)

5.60sqm/person

Occupant load for stores( upper floors)

9.30sqm/person

Occupant load for offices

0.65sqm/person

Occupant load for Auditoriums,theaters, churches, stadiums

2 exits

occupant load of more than 10 shall have at least

two stairways

A mezzanine floor bigger than 185sqm or having more than 18.00m in any dimension shall have at least ________to an adjacent floor

3 exits

occupant load of 500-999 shall have at least

4 exits

occupant load of 1000 or more shall have at least

Occupant load/165

Total width of exits

1/5

If two exits are required, the two exits must be apart by at least ________ of the perimeter of the area served.

45.00m

Distance to exits If without a sprinkler system

60.00m

Distance to exits If with a sprinkler system.

exit travel

When serving an occupant load of 50 or more, must swing in the direction of

true

Double acting doors shall not be used as exits when serving a tributary load of more than 100.

1300 sq. cm.

when serving a tributary load of more than 100 a view panel of not less than _______ Must be provided

900mm

Minimum width of doorway

2.00m

Minimum height of doorway

0.70m

Minimum clear width of exitway

90 degress

Door Shall be capable of opening at least

1.20m

Maximum door leaf width

6.00m

Maximum length of dead end

1.10m

Stairway widths for Occupant load more than 50.

0.90m

Stairway widths for Occupant load 50 or less

0.75m

Stairway widths for Occupant load less than 10 (private)

100mm

Handrails shall not reduce the width of stairways by more than

200mm by 250mm

Maximum riser and Minimum tread

2.00m

minimum headroom

3.60m

Max. vertical distance between landings

800-900mm

Height of handrails

250mm

Winding stairways Allowed as exits as long as the required tread______ is provided at a point 300mm away from the narrow end

250mm

Circular stairways May be used as exits provided that the minimum width of run is not less than

0.80m

Aisles if serving only one side

1.00m

Aisles if serving both sides

840mm

Standard seats Back-to-back distance

450mm

Standard seats Width

600mm

Grandstands/bleachers Back-to-back distance if without backrests

850mm

Grandstands/bleachers Back-to-back distance if with backrests or chair seating

450mm

Grandstands/bleachers Width

400mm

Grandstands/bleachers rise

200 sqm

Automatic fire extinguishing systems are required for Habitable storeys with an area of ________ or more with an occupant load of more than 20

10

Automatic fire extinguishing systems are required for Dressing rooms, rehearsal rooms, workshops or factories with occupant load of more than

4

All buildings _____or more storeys in height shall be equipped with one or more dry standpipes

300mm-1200mm above grade

Siamese connections shall be located on the street-front of a building

2.50m

Clearance of service drops from highest point of roofs

3.00m

Clearance of service drops from the ground

1.00m (horizontal)

Clearance of service drops from windows/porches

5.50m

Clearance of service drops from the crown of the street or sidewalk

4

Maximum elevators in a single hoistway

600mm

Hoistway pit from underside of car to bottom of pit

30 degress

Maximum inclination of escalators

560mm-1200mm

Escalators Width between ballustrades

90-120 fpm/27.5-36.5mpm

speed of escalator

1.20m

Projecting signs On non-arcaded RROW shall not be more than

0.60m

Projecting signs On arcaded RROW shall not be less than

0.30

Projecting signs on Buildings abutting RROW without sidewalks shall not be more than

3.00m from road surface to lowest part of signs

Projecting signs Minimum vertical clearance Non-arcaded RROW

5.00m from road surface to lowest part of signs

Projecting signs Minimum vertical clearance Arcaded RROW

3.00m

height of canopies/marquees: : _ m

2.40m

height of awnings from the surface of side walk

600, 600

attic access opening shall not be less than _ mm square or _ mm in diameter.

800

minimum clear headroom of _ mm shall be provided above the access opening.

250sqm

enclosed attic spaces of combustible construction shall be divided into horizontal areas not exceeding _________ sqm by fire-resistive partitions extending from the ceiling to the roof.

750sqm

except, that where the entire attic is equipped with approved automatic fire-extinguishing system, the attic space may be divided into areas not exceed _________ sqm.