- Front
- Back
Oil system |
|
|
Oil system |
|
|
Water supply system |
*Technology Cooling of the generator with the most amount, about 80% of all water *Fire control Fire control, flux larger than 15 Liter/s, can get to the highest possible fireLiving *Water supply way - Head within 20 m-80 m, water supply by gravity,from upstream(near dam,penstock in house, near turbine cover) - Head<20 m & head >80 m, pump,from downstream or underground |
|
Water drainage system |
*Seepage drainage Seepage water, living waste water, technology waste waterGravity flow, water-collecting well * Maintenance drainage Gravity flow first, then use drainage equipment Four types: *Water-collecting well: the draft tubes are connected with the pipe, the water can flow to the water-collecting well *Collection gallery: in the bottom of the station, no water-collecting well *District drainage: two units, one water-collecting well *Moving pump: water-collecting well for every unit, move the pump |
|
Air system |
Functions: Oil tank, 2/3 are compressed air; braking of generator; close to butterfly valve; Function -control the level of tail water in draft tube; - high voltage switchyard; pneumatic tools; High pressure system(25 atmospheres) Oil pressure system Low pressure system(5-7 atmospheres) - Blow the assembly place, the turbine layer, or the auxiliary building Far away from the central control room (noise) |