Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
110 Cards in this Set
- Front
- Back
What is a physical property of x-rays?
|
Travel in straight lines
|
|
As the wavelength of x-ray photons shortens, the energy of the x-ray bean will? (Increase or decrease)
|
Increase
|
|
Kvp setting on an x-ray machine controls the?
|
Quality of the x-ray beam
|
|
The mAs setting on an x-ray machine controls the?
|
Quantity of x-rays emitted
|
|
During an exposure, electrons in the x-ray tube travel from the?
|
Cathode to the anode
CAT=cathode-->anode-->target |
|
To produce x-rays, a great deal of energy in an x-ray tube is converted into heat. The ratio of heat generated to x-ray production is generally conosidered to be?
|
99% : 1%
|
|
The acceleration of the electrons and their ultimate striking energy is determined by the?
|
kVp
|
|
When depressing the "prep" switch on a rotating anode x-ray machine, you are effectively?
|
Heating up the filament and spinning the rotating anode
|
|
Regarding the production of x-rays in the x-ray tube the
|
Cathode includes the filament and the focusing cup
|
|
What transformer in an x-ray machine controls the temperature of the filament?
|
Step down transformer
|
|
The heel effect is going to be more noticeable with?
|
Larger film, shorter focal film distance and lower kVp
|
|
Full wave rectifications means that?
|
120 pulses of x-rays are produced per second
|
|
What is the minimum distance in feet that a safelight in the darkroom should be away from the work site?
|
4ft
|
|
If using both blue and green sensitive films, what type of safelight should you use?
|
Red
|
|
The main purpose of the x-ray developer is to?
|
Concert the exposed silver halide crystals into black metallic silver
|
|
The main purpose of the x-ray fixer is to?
|
Clear away the unexposed, undeveloped silver halide crystals
|
|
A safelight illumination test was performed in the darkroom. On processing the film, you see various gradations of blackness on your film. The area exposed for the longest period of time is?
|
Darkest
|
|
After you manually process a film, you notice that there is a green area of about 1/2 inch along one narrow edge of the film. This is due to the area not being?
|
Developed or fixed
|
|
Clear line at the top of the shorter edge of a radiograph that you have manually processed. This is due to the area not being?
|
Developed
|
|
You are looking at a film that is totally clear except for a bit of black that you notice along the edges. Your film has not been?
|
Exposed to radiation
(*black on film is from light leak) |
|
A film has a relatively clear edge all the way around the radiograph. This is because of?
|
Collimation
|
|
The remaining silver halide crystals from exposed x-ray film are removed in the?
|
Fixer
|
|
What would cause the image on a processed x-ray film to be fogged?
|
Film stored in an area of high room temperature.
|
|
What should be the maximum intensity of the bulb in a safelight in developing rooms?
|
15 watts
|
|
A bullet fragment on a film appears as a?
|
White mark
|
|
A crease in the film after exposure but before processing will likely appear as a?
|
Black crescent mark
|
|
Safelight fogging on a radiograph appears as a?
|
Diffuse grayish area
|
|
The cells that are most susceptible to the hazards of ionizing radiation are?
|
Rapidly dividing cells of the intestinal lining, neoplastic cells, and gonad cells.
|
|
A sievert (Sv) is the
|
Unit of radiation dose equivalent to the absorbed dose in tissue.
|
|
A radiation film badge worn at the collar level
|
Monitors exposure of the thyroid gland and lenses of the eyes.
|
|
When taking radiographs you should whenever possible use?
|
Decreased exposure time, increased distance from radiation, and increased shielding.
|
|
A small filament produces an image of
|
Greater detail than a large filament
|
|
If you were going to decrease the focal film distance from 100 cm to 50 cm, what should your new mAs be if the old mAs was 16?
|
4.0 mAs
|
|
Scatter radiation on a film is more noticeable if there is
|
Higher kVp, thicker patient, and larger field size
|
|
To get more density on a film you should do what to the kVp and mAs?
|
Increase either or both
|
|
Because of the relationship between mA and mAs, as you increase the mA you can
|
Decrease the length of the exposure so that there is less chance of movement
|
|
The crystal of high speed screens as compared to similar types of par screens are
|
Bigger, and there is less detail
|
|
The main advantage of fast speed screens and films is that
|
Lower exposure factors can be used which can allow use of a smaller focal spot.
|
|
If using rare earth screens what spectrum of light must the film be sensitive to?
|
Green range
|
|
a radiograph appears gray overall. This is best described as a
|
Low contrast film with many steps but few changes between each step.
|
|
Grid cutoff can be described as
|
Incorrect use of the grid so that the grid absorbs more radiation than it should
|
|
A dog is lying in left lateral recumbency for a pelvis radiograph. The right femur will be
|
more magnified because of decreased focal film distance and increased object film distance.
|
|
In a lateral pelvic projection the affected limb should be
|
Closest to the film and pulled slightly cranially
|
|
The term dorsomedial-plantarolateral oblique is in reference to the?
|
Metatarsus
|
|
The term dorsomedial-plantarolateral obique means that the x-ray bean is directed at the
|
Dorsal limb aspect, and the film is against the lateral side of the limb.
|
|
For proper radiographic exposure, a radiograph should be taken during maximum
|
Expiration for abdomen
Inspiration for the thorax |
|
Best view of the elbow is
|
Craniocaudal
|
|
Peripheral borders for an elbow radiograph are
|
1/3 of the radius/ulna and 1/3 humerus
|
|
The cranial and caudal borders for a lateral abdomen should be
|
The eighth rib and femoral head
|
|
Best view for tympanic bullae is
|
Open mouthed rostrocaudal
|
|
For a DV view of the entire skull, you should center the primary beam
|
Between lateral canthi on sagittal crest
|
|
To ensure that your Dv radiograph for the skull is parallel and perpendicular you should try to have
|
An imaginary line drawn between the medial canthi parallel to the film.
|
|
Required to take intraoral radiographs of the teeth of a labrador. You are to use your regular x-ray machine and the animal is anesthetized. you should use
|
Nonscreen film
|
|
For cervical studies you should center the primary beam at
|
C3 to C4
(7 Cervical Vertebrae) |
|
The femurs in a hip dysplasia view appear foreshortened. This is likely due to not having the
|
Femurs parallel to the cassette
|
|
Positive contrast media are considered to be
|
Radiopaque, which means it will be White on a processed film
|
|
The triiodinated compound that is least irritating to the GI tissues and has less toxicity is the
|
Meglumine diatrizoic salt
|
|
The positive contrast compound that does not influence the movement of fluid through the intestinal wall
|
Barium sulfate preparation
|
|
An IV pyelogram is also referred to as a
|
Excretory urogram
|
|
An upper GI study is performed to evaluate
|
Stomach and small intestine
|
|
The film focal distance for a dental radiograph machine is
|
16 inches
|
|
The exposure factor that is responsible for accelerating the electrons from the cathode to the anode is
|
kVp
|
|
The temperature of the cathode filament is controlled by
|
mA
|
|
The nine penny test is a quality control test for
|
Light field/x-ray field alignment
|
|
Elongation and foreshortening of anatomic structure are associated with
|
Geometric distorion
|
|
A tabletop (nongrid) technique is used to radiograph the
|
Extremity
|
|
Sante's rule is used to calculate
|
kVp
|
|
If the mA is 300 and the time is set at 1/60 the mAs is
|
5
(300/60=5) |
|
A special study that involves use of a negative contrast media is
|
Pneumocystogram
|
|
The field of view of the pelvis for OFA includes
|
Pelvis, femurs, and stifles
|
|
Standing lateral view of the thorax with a horizontal beam is used to confirm the presence of
|
Fluid or free air
|
|
A skyline view is used to radiograph what part of a horses anatomy
|
carpus
|
|
Bisecting angle technique is associated with taking an x-ray of the
|
teeth
|
|
To determine whether an animal had an ununited anconeal process the veterinarian would want you to x-ray the
|
Elbow
|
|
The pH of the fixer chemicals is
|
Acidic
|
|
The ideal temperature of the chemicals for manual radiograph processing is
|
68 degrees
|
|
Nonscreen film would most likely be used to take what type of radiograph
|
Dental
|
|
An x-ray film exposed to visible light and developed would appear
|
Black
|
|
An x-ray film accidentally developed before exposure to radiation appears
|
Clear
|
|
A new x-ray film taken directly from the box appears
|
Green
|
|
All artifacts appear as clear or white marks on film except
|
Crimping or folding of the film
|
|
If a radiograph is too light and the image appears underpenetrated you should
|
Increase kVp 10% to 15%
|
|
If the image is too light but the image shows adequate penetration you should
|
IncreasemAs 30-50%
|
|
If a film is too dark and the image appears overpenetrated you should
|
Decrease kVp 10-15%
|
|
Mitchell markers are primarily used in standing radiography of the equine head to assist in identifying
|
Fluid levels in paranasal sinuses
|
|
The unit of absorbed ionizing radiation dose is
|
Gray (Gy)
|
|
If cracks are present in protective apparel they appear what color when radiographed
|
Black
|
|
One sievert (Sv) equals
|
100 rem
|
|
a noninvasive imaging procedure that uses a small amount of radioactive material administed IV is
|
Scintigraphy
|
|
The ultrasound term that refers to few echoes detected and the area is a low level gray compared with the surrounding tissue is
|
Hypoechoic
|
|
The imagine technique that uses x-rays and computers to produce images that show anatomy in a cross section is
|
CT
|
|
What involves no ionizing radiation to create the image
|
MRI
|
|
The maximum permissible dose for whole body radiation per year in sieverts is
|
0.05 Sv
|
|
Tabletop exposures can usually be made under which of the following circumstances
|
When the area of interest is less than 10 cm thick
|
|
Lateral thoracic radiographs are taken at
|
peak inspiration
|
|
Which views must be taken to properly perform a thoracic metastasis check on a patient with mammary adenocarcinoma
|
Right and left lateral views and a VD or a DV view
|
|
Which lung field is best visualized in an animal that is in left lateral recumbency
|
Right lung field
|
|
Attribute a yellowing of radiographic films to
|
Incomplete washing of processing chemicals
|
|
To take advantage of the heel effect
|
Place the thickest part of the patient toward the cathode side of the x-ray tube
|
|
The palmar surface of the forelimb refers to
|
The caudal surface of the forelimb distal to the carpus
|
|
What information can a barium impregnated polyethylene spheres study provide
|
Information about gastric transit time
|
|
The information yielded with nuclear scintigraphy includes what
|
Physiologic information about the function of the organ under study
|
|
what contrast media is contraindicated with perforations
|
Barium sulfate
|
|
Hypoechoic tissues have what characteristics in an ultrasonic study
|
Reflect few echoes that result in low level grays on the screen
|
|
High frequency ultrasound unit transducer
|
Increases resolution and decreases penetration
|
|
a bladder stone is hyperechoic what type of image does this project on the ultrasound monitor
|
Bright white image
|
|
a urine filled bladder is usually best classified as
|
anechoic
|
|
The tungsten plage (target) is located where on the x-ray machine
|
anode
|
|
In an x-ray tube, x-rays are formed on the
|
tungsten target on the anode
|
|
The distance between the x-ray tube and the film is the
|
focal film distance
|