3 Cards in this Set

  • Front
  • Back

Scope of Chief regular 4 program

the chief regulation 4 program is testing program intended to ensure maintenance of fire protection equipment and systems continue to function at the same level as originally intended to operate in the corners with the code in effect when the new system is installed on an existing system has been upgraded once the system is accepted by the fire of a building department each system where equipment is required to have the entire system tested at either one or five-year intervals also known as reg for initial test which is performed on the system requipment anniversary testing date

Scope

when is system of equipment is it at state of obvious despair in a manner which makes a system equipment unable to test a ignition test shall not be performed and therefore no test report issue the owner owner's representative initiated repair immediately disrepair is normally initiated by notice of violation issued by the fire department wants to approve repairs made the initial Chief regulation 4 test is required.the initial test procedure is intended to test the entire system to determine the operating condition of the equipment or system being tested system defects are found doing the initial test the fire department will require the defective component to be repaired and retested through store the equipment to proper operating condition.sometimes it is found that the equipment was installed in a manner inconsistent with the applicable codes and policies and the original acceptance test did not uncover the despair Arc or in some cases certain retroactive provisions may be applicable to equipment at the decision of the fire department the result of Chief regulation for text may be used to initiate the system upgrade

Scoped

in 2006 the State fire Marshal mandated a program of inspection testing and maintenance of water-based fire protection system which is almost identical to the provisions of Chief regulation number for program these provisions are commonly known as California code of regulations title 19/ NFPA 25 inspection testing and maintenance.