WUCOMS Foam extinguisher |
U - Class B, A, F Fires C - Red with blue band, stainless steel cylinder, 8.4L water & 600ml concentrate, pressured to 700kpa, valve assemble, delivery hose with aspirating nozzle O - PASS distance of 5m lasting 45 secs M - inspect all components, if fails or even partially used send to zone station for exchange S - wear appropriate PPE, Be aware of re-ignition if foam blanket disturbed |
|
WUCOMS water extinguisher |
U - A class fires C - 9L water @700kpa, red, stainless steel cylinder, valve assembly O - PASS - 6m for 1 minute M - inspect all components, if failure or even partially used exchange at zone station S - appropriate PPC |
|
W - Co2 extinguisher |
U - A, B, E, F class fires C - Drawn steel @5.2MPa, red with black band, valve assembly, non conducting director horn, safety valve operates @ 17.2MPa O - PASS 1-2m for 15 seconds M - inspect all components, exchange if fails check or even partly used S - wear appropriate PPC, slight cooling effect, can re-ignite |
|
W - Dry chemical extinguisher |
U - A, B, E, C class fires C - welded steel cylinder 9 kg mono ammonium phosphate/nitrogen, red with white band, valve assembly, nylon pvc hose with polypropylene applicator O - PASS 3-4m for 20 seconds M - isnpect all components, if fails or even partially used send to zone station for exchange S - wear appropriate PPC |
|
Rabbit Tool |
U - forcible entry C - hydraulic hand pump, small ram with stainles steel jaws, 4ton capacity, 1.8m re-inforced rubber hose, rubber mallet, pry bar O - 2 person operation, teeth into door crack and pump hydraulic handle to open teeth M - clean with damp cloth, check for leaks in hose and connections S - correct PPC, 2 people, door may spring open, beware of kinks etc in hose, 4tonne pressure can penetrate skin |
|
W - Standpipe |
U - access water from street main via ground ball C - go through all parts O - shipping procedure M - clean with damp cloth, check all parts for damage, fill in p798 if damaged and notify OIC S - correct PPC, never place head and shoulders over standpipe |
|
W - ceiling hook |
U - remove ceilings, pierce ceilings to releive water buildup, remove overhead debris, forcible entry, overhaul C - wooden handle and metal spur, bevelled edge for cutting O - pierce, use bevelled edge to cut M - clean with damp cloth, check for damage S - PPC, falling debris, broken glass left in window fram |
|
W - fuse puller |
U - disconnect power supply to structure C - rubber coated pole, 2 end piece adaptors, threaded holder and swing down box O - procedure as taught M - clean with damp cloth, check for damage S - correct PPC with rubber electrical gloves, beware of water |
|
W - TAC stick |
U - detects presence of live AC, confirm and monitor that AC electricity has been isolated C - sensor, setting switch, LED, handle, lanyard, beeper O - twist to high sensitivity, will self test, then move around slowly to detect prescence, has high/low sensitivity and front focused M - clean with soft cloth, never immerse in liquid, if dropped return to workshops, change of shift teat, batteries S - correct PPC, treat all wires as live, auto/remote reclosures, alert to possibility of stored DC power |
|
W - collapsible knapsack |
U - A class fires C - shoulder straps, hand pump, hose, 19L flexi-pack knapsack re-enforced pvc. O - fill with water, wear as backpack, pump handle for single squirt M - check integrity of knapsack, hoses and connectors for holes, splits and leaks S - correct PPC, consider that you only have 19 litres |
|
W - Blitzfire Monitor |
U - rubbish tip fires, any long stationary positions C - TFT head, pivoting inlet and outlet (20 degrees either side horizontal, 10 degrees to 50 degrees vertical) , folding legs with carbide tipped spike, valve handle with locking knob O - ensure legs are unfolded, tie off, two people, two feeds into truck, two deliveries into monitor, pivot to desired position M - wipe down with damp cloth, check all parts for damage, flush after use with foam S - 1200kpa, 2 people, legs extended, tied off |