The maximum distance between the vent and the trap is measured from the____________ to the _____________

Trap weir to the vent pipe fitting

The maximum allowable drop on a horizontal drain and the vent pipe connection must not exceed_________

The diameter of the trap arm

Distance between the vent and the trap must not be less_____________

Then Twice the size of the fixture drain

The maximum allowable distance of the fixture and trap must not exceed

36"

A fix your dream pipes to a drain through one complete story minimum is called a

Soil or waste stack

Flat vent is a trade name for a vent that

Requires a clean out fitting to be placed

A branch vent

Is 2 or more dry vents connected together

An individual vent becomes a stack vent when

A fixture drain extends through at least one complete story

The Continuous waste and vent principal connection is considered as the best arrangement for venting because

Waste water does not enter the vent pipe

A vent connection fitting placed on a trap arm

Must have the vent opening arranged above horizontal center line of the trap arm

Which rangement me allow a fixture to self siphon

Trap too far below fixture

A 3" stack vent is required in a residence because of

The national piping code of Canada

The minimum drainage pipe size required for a lavatory is

1 and 1/4 inch

Vent pipe roof flashing material must be compatible with the vent pipe material to avoid

Electro chemical corrosion

What is the primary function of a trap

Keeps sewer gas from entering into a building

Which of the following trapp's is prohibited from use in a single plumbing system

Bell trap

What is the maximum trap seal depth for all traps except for those that drain acid wastes

1 and 1/2 inches

What kind of safe and age occurs when the fixture outlet pipe is excessively long

Momentum syphonage

What would be the size of a trap that serves to lavatories that are in the same Room

1 and 1/2 inches

What would Happen if the fall on a tramp arm was more than one pipe diameter

The trap may self syphon