The technical order for ESD information can be found in
|
TO 00-25-234
|
|
What means of static generation can cause the highest electrostatic voltages
|
Walking across carpet
|
|
Walking across carpet can produce how many electrostatic voltages
|
35,000
|
|
The level of voltage required for a human being to feel a static discharge is approximately
|
3,500V
|
|
Three types of failures caused by ESD are
|
Intermittent, Latent, Catastrophic
|
|
Certain technologies of parts are inherently sensitive to ESD and can fail at any voltage level between
|
0-16,000 volts
|
|
The personnel wrist straps shall be worn when working on energized parts, assemblies and equipment
|
False
|
|
What is required anytime an ESD sensitive item is stored or transported
|
ESD protective packaging
|
|
To seal/close ESD protective packaging you may use
|
Non-Charge generating tapes
|
|
What DC current value is usually fatal to human beings?
|
300mA
|
|
Three factors that determine the severity of electrical shock are
|
Magnitude, Duration, Path
|
|
When cleaning ESD sensitive items what type of isopropyl alcohol must be used
|
70%
|
|
For QA purpose a log shall be kept for daily initial test, the log will include
|
Date, Time, Results, User name
|
|
Wrist straps will be periodically tested
|
Before initial use each day
|
|
Persons working at ESD control workistations while circuit board repair is done shall roll up shirt sleeves above the elbow prior to and during repair
|
True
|
|
Basic static control workstations consist of three components, what are they
|
Personal wrist strap, Common point ground system (CPGS), Static dissipative work surface
|
|
The periodic performance test interval for solder guns or irons is
|
Quarterly
|
|
Areas utilizing static dissipative flooring shall not wax or apply any topical coatings of any kind. Standard floor cleaning procedures shall be used.
|
True
|
|
After testing the integrity of a wrist strap cuff and cord, the resistance for the strap and cord shall be between
|
1-10 mega ohms
|
|
The single most important item for effective static control is
|
Personnel wrist strap
|
|
When does ESD susceptibility stop
|
after item is correctly packaged
|
|
Some of today's circuits are sensitive to voltages as low as
|
25V
|
|
Common plastic bags picked up from a bench can cause electrostatic voltages of
|
20,000
|
|
An ohmmeter is used to check the integrity of grounding conductors and bonding for esd controlled
|
workstations, cabinets, floors
|
|
To prevent ESD damage, personnel should be using correct hardware, equipment, and be
|
Properly trained
|
|
Electronic parts considered SUPERSENSITIVE have revealed voltage sensitivities between
|
0-999 volts
|
|
What type of brush will be used prior to and during the cleaning of ESD sensitive items
|
Camel hair brush
|
|
Plastic or insullative/non-conductive materials shall be used on or around esd sensitive items
|
False
|
|
ESD items can check out electrically on the repair/test bench, but fail on the end item when subjected to stresses or applying normal operating voltages
|
True
|
|
What is the periodic interval for testing Work Surfaces
|
Semi-annually
|
|
The camel hair brush must be wet with a _________ isopropyl alcohol or greater, ________ to and during cleaning of ESD items
|
70%.........Prior
|
|
What are the three factors that determine the severity of electrical shock
|
Magnitude of current flowing through the body, path of current through the body and duration of time that the current flows through the body
|
|
How should raised floors be grounded
|
Using a No. 8 copper wire for bonding between pedestal and verified ground point. Using an oxide inhibitor between the base metal of the raised floor pedistal and copper connection
|
|
What is the ohm rating of the resistor used in the wrist strap cord
|
1 mega ohm
|
|
What is the ESD sensitivity voltage range for components classified as SENSITIVE
|
0-16000 Volts
|
|
Walking over a vinyl floor generates how much electrostatic voltage
|
12,000 Volts
|
|
What is the periodic interval for testing storage cabinets and flooring
|
Annually, Annually
|
|
The voltage to produce a fatal current depends on what
|
Resistance of the body, contact conditions and path through the body
|
|
You can seal ESD items in a bag with the following items, masking tape, scotch tape, duct tape
|
False
|
|
What are the four types of static control workstations
|
Permanent static control workstation, workstation with rigid work surface, workstation with cushioned work surface and portable workstation
|
|
What mil standard covers Test Methods and Procedures for Microelectronics
|
MIL-STD-883
|
|
All personnel who handle, operate, remove or install ESDS items must be _________ or _________ to the items
|
Grounded or bonded
|
|
Prior to removing or installing conductive caps, personnel shall
|
Touch (with bare skin) and maintain contact with a metal portion of the items case or chassis
|
|
If type 1 bags are used how should parts be initially wrapped
|
In non-generation material
|
|
Bags containing ESDS items should be sealed or closed
|
True
|
|
How ESDS items should be transported
|
In static shielding and non-charge generating packages or containers
|
|
After a qrist strap inspection is performed what should you do
|
Document a log with date, time, results and user name for QA purposes
|
|
A worker sliding in a chair padded with polyurethane will generate how much electrostatic voltage
|
18,000 volts
|
|
Opening and closing a vinyl envelope will generate how much electrostatic voltage
|
7,000 Volts
|
|
A worker moving at a bench will generate how much electrostatic voltage
|
6,999 Volts
|