AN ELECTRICAL SHOCK OCCURS WHEN WHAT?

A CURRENT PASSES THROUGH THE HUMAN BODY. THE CURRENT WILL FLOW THROUGH THE BODY'S NERVOUS SYSTEM OR VASCULAR SYSTEM TO GROUND.
ELECTRICAL SHOCK DISRUPTS THE BODY'S WHAT?

NORMAL ELECTRICAL FUNCTIONS (POSSIBLY STOPPING THE HEART, LUNGS OR BOTH/ POSSIBLY CAUSING DEATH)

EXTERNAL POWER MUST BE DISCONNECTED AND AIRCRAFT POWER REMOVED PRIOR TO WHAT?

ENTERING LOAD CNTERS TO REMOVE OR INSTALL ELECTRICAL COMPONENTS
WHAT IS VOLTAGE

THE ELECTRICAL FORCE WHICH CAUSES CURRENT TO FLOW IN A CIRCUIT (MEASURED IN VOLTS ((v))

ELECTRICAL CURRENT IS WHAT

THE MOVEMENT OF ELECTRICAL CHARGE THROUGH THE ELECTRONIC CIRCUIT (MEASURED IN AMPERES)

RESISTANCE CAUSES WHAT

AN OPPOSITION TO THE FLOW OF ELECTRICITY IN A CIRCUIT
RESISTANCE CONTROLS THE AMOUNT OF WHAT

VOLTAGE AND OR AMPERAGE IN A CIRCUIT

RESISTANCE IS MEASURED IN WHAT

HERTZ (Hz)

WHAT IS A BUS?

A DISTRIBUTION POINT IN AN AIRCRAFT ELECTRICAL SYSTEM TO WHICH THE BATTERYU AND THE GENERATORS ARE CONNECTED. (COMPONENTS THE DERIVE THEIR POWER FROM THE BUS

AC GENERATOR

GENERATOR MOUNTED TO EACH ENGINE REDUCTION GEAR DRIVE OF ENGINES 2, 3, AND 4. THE ENGINE REDUCTION GEAR IS PROTECTED FROM POSSIBLE DAMAGE SHOULD THE GENERATOR SEIZE BY A SHEAR ON A GENERATOR STUB SHAFT. A GEN OFF LIGHT INDICATOR LOCATED ON THE RIGHT INBOARD OVERHEAD FLIGHT STATION PANEL ILLUMINATES WITH A FAILURE OF ANY OF THE ENGINE DRIVEN GENERATORS
THE APU AC GENERATOR IS IDENTICAL TO THE GENERATORS USED ON # 2, 3, AND 4 ENGINES EXEPT FOR WHAT?


COOLING BELL HOUSING



IN ADDITION TO THE TRANSFER RELAYS OTHER RELAYS ARE EMPLOYED IN THE AC POWERE DITRIBUTION TYSTEM TO WHAT

CONNECT AND CONTROL THE POWER TO THE BUSES

SENSING RELAYS ARE IDENTICAL AND INTERCHANGEABLE AND DO NOT ENERGIZE UNLESS WHAT

THE GENERATOR VOLTAGE AND FREQUENCY ARE CORRECT

WHER ARE THE SENSING RELAYS LOCATED

IN THE MAIN AND FORWARD LOAD CENTERS
where and why are circuit breakers installed
on panels throughout the aircraft to protect the various electrical circuits (current limiters provided where necessary)
what kind of circuit breakers are used in the electrical system
push pull type
how many vr/supervisory panels are there?
4 in the main load center (identical and interchangeable)
what does the vr/supervisory panel provide?
control of the generator and connects it to the bus transfer system
where is the 1 24 volt battery located
in the aft section of the nose wheel well (normally used to start the apu
what is the battery capable of powering?
most dc busses for a limited time in the event all other dc sources fail
when does the battery receive a continuous charge?
under normal operation