- Front
- Back
ASID Code of Ethics- Professional Conduct
|
We protect the :
health, safety and general welfare of the public. |
|
Arch dwgs.- 3 types
|
- Idea generation
- Design and presentation - Guide for construction process |
|
LEED- Leadership in Energy and Environmental Design
|
People- accredited
Buildings- certifies |
|
Programming Phase
|
- Bubble diagrams and Adjacency matrices
- work with relative sizes of spaces |
|
Universal Design is NOT the same as Accesibility
|
Universal- providing access for EVERYONE
Accessibility- provide access for DISABLED |
|
BIM- Building Information Modeling
|
Revit Software
|
|
Lineweight
|
Relative width and intensity of a line
|
|
Lineweight: Broken-down
|
LIGHT- Patterns (tile, grout)
MED- Dimensions, extension lines, leaders, arrows, break lines MED/DARK- Objects, hidden, center lines DARK- Borders, Sections |
|
Lines: Broken-down
|
DASHED- hidden, above elements
CENTER- symetrica, center of objects CONTINUOUS- normal, objects, walls DIMENSION- distance CUTTING- sections LEADER- extends from text to point to object BREAK- object not drawn in entirety |
|
Standard Lettering
|
Roman Alphabet in ALL CAPS
|
|
5 Phases of Design Process
|
Programming
Schematic Design Design Developement Construction Documents Construction Administration |
|
Schematic Phase
|
important to have client approve and sign off on final schematic plan
|
|
CD Phase- General Contractor
|
only general contractor can stop work if it's not going according to plan. Owner must talk to GC, designer cannot.
|
|
CD Phase- Approval
|
Designer can't sign off on furniture approval after delivery. Only client can.
|
|
Error and Omissions Insurance
|
GC should carry this
|
|
DWG- 2 main categories
|
Architectural & Engineering
|
|
Project Manual/Job Book
|
Technical specs apear here, if there are not many specs (smaller proj) they may go directly on dwgs.
|
|
CLOSED Spec
|
Only use exact product that is specified.
|
|
OPEN Spec
|
Similar products can be substituted.
|
|
Proprietary Spec
|
Closed, most restrictive. specific man, easiest to write, shortest, no comp. bidding
|
|
Descriptive Spec
|
Open, less restrictive, no specific man, use this when no standards need to be met, calls out materials, finishes, installation methods etc.
|
|
Reference Spec
|
Open, less restrictive, no specific man, does reference standards, competitive, (shorter and easier to write than Desc. Spec)
|
|
Performance Spec
|
Open, less restrictive, no specific man, describes expected performance, longer, rarely used for interior construction
|
|
MasterFormat
|
standard used when writing specs, developed by CSI
|
|
As Built Dwgs- Lineweights
|
DEMO- Darkest (blue)
TEXT- Middle (yellow) EXISTING- Light (grey/red) |
|
Column Floor Plan Grid
|
#'s across top
A's across side |