what is the minimum service clearance to the control side of a boiler

24"

a condensing appliance will generally have a vent temp no more than

125°f

min length of a hose permitted for a construction heater is

15'

flame rectification relies on what of the flame

conductivity

typical spark ignition voltage for IPi system would be

10-30 KV ac

on a flame safe guard system using a flame rectification the rectified signal is generally the range of

1-10 micro amps

minimum spark gap on ipi system

1/8"

which requires the highest voltage to operate

spark gap

the VA rating on a transformer indicates what

the capacity rating

if the high limit is installed on the ordinary voltage what does it control

transformer

what would you use to test the integrity of the valve coil

ohm meter

high limit on forced air furnace is set between what range

180-250 °f

the fame control on a forced air furnace is generally set at

130°f cut in 90°f cut out

how is a mercury thermostat installed

4-5 feet above the floor


installed level

what is used to properly adjust the anticipatory

the amperage reading from the control circuit

when over 400mbh power burners are size as

1 sq " per 30.000 btu

excess air volume are accurately measured at

in the flue gases of the heat exchanger

what is the smallest vent allowed in the venting system

3"

the valve that must be on all propane cylinders is

relief valve

ipi system ground strap is how many times larger than the ignitor and what power is it

4 times larger than ignitor and it produces DC voltages conducted through flame

min spark jump and what's solution if minimum not reached

1/4-3/8


if doesnt reach minimum module must be replaced transformer not interchangeable

pressure rating for propane cylinder

240 psig

how often does a cylinder need to be recertified

every 10 years

relief valve if a cylinder must be in contact with what

must be in contact with the vapour space of a cylinder at all times

min distance if discharge if propane relief valve and mechanical air intake of a building

10 ft

propane internal relief valve set at what?

375 psig

what size is spit valve orfice

54

cylinder can be filled to a max of what

water capacity 42%


liquid level gauge 80%

max hose length for propane appliances

30 feet

average 100lb porpqne cylinder will supply how much btuh

50,000 btuh

how far must a vaporizer be from a building air intake or opening

25 ft