Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
18 Cards in this Set
- Front
- Back
Weight used to check magnetic strength of an AC yoke |
10 pounds |
|
Weight used to check magnetic strength of a DC yoke |
40lbs |
|
When performing a visual exam, the minimum angle of eye to part |
30° |
|
Hole size that must be visible in RT when using a hole- type IQI |
2T |
|
Maximum allowed thickness on a WPS based on the plate thickness (T) of a PQR test coupon |
2T |
|
Minimum light intensity when performing VT, MT or PT exams |
100 foot – candles |
|
Minimum black light intensity when performing MT or PT exams |
1000 microwatts/cm squared |
|
Lead letter used during RT to check for backscatter radiation |
B |
|
Lead letter used during RT to indicate a film – side IQI |
F |
|
Two primary Gamma – ray radiation sources |
Iridium, cobalt |
|
Two most common CS pipe materials |
A53 & A106 |
|
Maximum stress allowed during a pressure test |
90% of SMYS |
|
PH of hydrotest water needed to reduce likelihood of MIC (bugs) |
Greater than 10 PH |
|
Maximum allowed SMYS allowed for pipe if fillet– welded patch is installed |
40,000 PSI |
|
Typical external corrosion rate for dry rural environments |
Less than 1MPY |
|
Typical EXT corrosion rate for inland locations with moderate rain and humidity |
1-3MPY |
|
Possible EXT corrosion rate for industrial environment with acid or sulfur compounds |
5-10 mpy |
|
Possible EXT corrosion rate for marine environments |
20 mpy |