Thermochemical Sensor - Thermal Conductivity type. |
Responds to anything different from the carrier gas.
|
|
Combustion Sensor.
|
Wheatstone bridge.
|
|
Electrochemical Sensors - Conductive.
|
Ions conduct electricity. Gases for electrlytes in soln. andchange conductivity of that soln.
|
|
Electrochemical Sensors - Potentiometry.
|
Gases change the pH of soln.
|
|
Electrochemical Sensors - Coulometry.
|
The amount of electricity produced = contaminant present.
|
|
Electrochemical Sensors - Ionization.
|
Make the gas conductive so electrical field can collect particles.
|
|
Chacoal Tubes
|
Adsorbs vapor molecules.
Breakthrough of 10% = junk sample. Not good for: Amines, Phenols, nitrocompounds, aldehydes, or reactive comounds. |
|
Silica Gel Tubes
|
Electrically polar. Attracts polar molecules like H2O, ROH, aldehydes, amines, phenols, amides, and inorganic acids.
|
|
Diffusion Badges
|
Requires 15 fpm of airflow. Not as accurate as tubes.
|
|
Polycarbonate Filters
|
Better strength than membrane. Low collection efficiency.
|
|
Membrane Filters
|
High collection efficiency. Low ash, low weight. Good for gravimetric.
Bad at high temps. |
|
Mixed Fiber Filters
|
Used in air cleaning. High collection efficiency. Low pressure drop.
|
|
Glass Fiber Filters
|
Not as hygroscopic as cellulose. Good for high temps. Suitable for radio frequency ashing.
|
|
Cellulose Filters
|
Cheap, strong, many sizes. High background of heavy metals.
|
|
Mercury Sampling
|
Hopcalite.
Cold Vapor AAS. |
|
Fluoride Sampling
|
Treated MCEF.
|
|
Hexavalent Chromium Sampling
|
PVC Filter.
IC, UV/Visible. |
|
Asbestos Sampling
|
25 mm Open Faced MCEF.
PCM |
|
Fiber meassurement field area?
|
Af = 0.00785 mm2.
|
|
Fiber
|
Greater than 3:1 aspect ratio.
Use PCM, PLC, electron microscopy, SEM, or TEM. |
|
NIOSH Rule of Thumb regarding sample numbers.
|
> or = 6 samples for a valid estimate of confidence interval.
> 11 samples to estimate variance. |
|
NIOSH rules about blanks.
|
6 media blanks in lab.
2 field blanks for every 10 samples. |
|
Sample breakthrough.
|
If the sample media contains >10% in the back up section, the sample is junk.
|
|
Primary Standards
|
Mariotti bottle, spirometer, frictionless piston meter.
|
|
%Error = (Observed - expected)/Expected x 100
|
<5% good flowrates.
5-10 use lower flow rate >10% resample. |
|
Formaldehyde sampling
|
XAD-2
|
|
Miran
|
Type of IR analyzer.
|
|
Filters for particulate sampling:
|
GFF: Oil mist, pesticides.
MCEF: Metals, asbestos, dusts. PVC: Dusts, chromium VI PTFE: PNAs, CTPVs |
|
Asbestos filter area
Ac= |
Ac=385mm
|