  • Front
  • Back

Which would most likely be used to control the automatic pump shutoff, when all fuel is depleted from a fuel tank?

Float switches

Refueling by using the fuel level control valve is a much safer operation than filler neck refueling because the valves will...

Automatically stop the flow of fuel into a tank prior to ovwrflow

What principle is used to operate fuel level control valves?

Hydro mechanical

What part of a piston type fuel level control valve prevents fuel from entering the tank?

A pilot valve

Approximately how much (in percent) air space is left at the top of the fuel tanks of a cargo aircraft after ground refueling

3

Which cargo aircraft components should be operationally checked during the first few minutes of a ground refueling operation?

Fuel level control valves

What valve must be open to allow fuel to flow from a cargo aircraft spr to the main wing manifold during ground refueling?

Refuel isolation

When the FWD fuel system on the fighter aircraft is refueled, what tank will fill first?

FWD reservoir

You're preparing to troubleshoot a problem on the ground refueling system for a fighter aircraft. To do this properly, you would

Refer to the applicable TO

During refueling of a fighter aircraft, fuel was vented overboard and the refueling operation would not stop. The most probable cause of this problem is an inoperative...

Refuel shut off valve

What light on a bomber aircraft aerial refueling system let's a pilot know if all conditions are satisfied prior to boom and receptacle connection

Blue READY/NWS light

The aerial refueling circuitry on a bomber aerial refueling system is energised by the cam operated aerial refuel...

Pull-to-refuel switch

What action will generate command output signals from the electrical multiplex bus (EMUX) and energize the aerial refuel power supply on a bomber aircraft?

Pulling down the PULL REFUEL T-handle and placing the MODE switch in the NORM position

Which condition will result in an automatic disconnect of the boom and receptacle during aerial refueling on a bomber aircraft?

Boom travel limits are exceeded

A manual disconnect of the tanker and receiver on a bomber aircraft has been accomplished. What action will reset the universal aerial refueling receptacle slipway installation (UARRSI) and signal amplifier, causing the READY/NWS light to illuminate?

Placing the pilot trigger switch to the first detent

You are troubleshooting a malfunction in a bomber aerial refueling system. The fault code for the malfunction is 28-25-AM. What does the letter A indicate?

A fault isolation diagram is provided

You are troubleshooting a problem on a bomber aircraft. At a certain point, the fault isolation diagram requests that you enter a parameter monitor code (PMC). To comply with the request you would enter the code on the...

Central integrated test system (CITS) control and display panel in the aft crew station

What is the purpose of the cargo aircraft vent system?

Prevent overboard fuel spillage