DESCRIBE IN DETAIL WHAT HAPPENS TO THE DOCKS AIR SYSTEM ON A LOSS OF SHORE POWER TO CASUE THE DOCK TO GO INTO AIRLOCK?

-DOCK WILL GO INTO AIR LOCK


-ALL INTERCONNECT VALVES FAIL SHUT AND ALL DEBALLAST PUMP DISCHARGE VALVES WILL FAIL OPEN


-WHILE IN AIRLOCK, IF ELECTRICAL POWER IS AVAILABLE, FLOOD AND INTERCONNECT VALVES CAN BE ELECTRICALLY OPERATED (UP TO 5 OPER EACH VALVE)

WHAT ARE THE CONCERN IN ATTEMPTING TO OPERATE FLOOD VALVES IN MANUAL WHILE IN “AIR LOCK”

-DO NOT ATTEMPT TO OPERATE ANY FLOOD VALVES IN MANUAL WHILE DOCK IS IN AIR LOCK UNLESS THE EMERGENCY AIR ACCUMULATORS ARE FULLY DEPLETED


-ATTEMTING TO OPERATE FLOOD VALVES IN MANUAL WHEN AIR PRESSURE IS PRESENT WILL RESULT IN SHEARING THE MANUAL OPERATING PIN OR COUPLING KEYS.

2 THINGS

FOR AN OUT OF SPECIFICATION READING ON THE SOUNDING AND SECURITY LOG, WHAT 4 THINGS SHOUD BE ANNOTATED IN THE REMARKS SECTION?


ARCOINST 1601.4

1.WHAT THE READING IS AND THE TIME IT WAS DISCOVERED


2. SUSPECTED CAUSE


3. COURSE OF ACTION TO BE TAKEN


4. PERSON (S) NOTIFIED

PER ARCOINST 4790.4 PERSONNEL PERFORMING OR AUDITING TAG-OUTS SHALL BE QUALIFIED IN WHAT PQS?

3M-301 MAINTENANCE PERSON


QA-301 CRAFTSMAN

LIST THE REQUIRED CRANE CREW WATCHSTANDERS FOR A. NON CRITICAL LIFT, AND B, CRITICAL LIFT. ARCOINST 9900.4N

NON CRITICAL LIFT (6)


SIGNALMAN, OPERATOR,RIGGER, TAG HANDLER,TRACKWALKER,CRANE TECH


CRITICAL LIFT


CRITICAL SIGNALMAN,CRITICAL OPERATOR,SAFETY OBSERVER,SECOND TAG, CRANE TECH

LIST AS MANY OF THE 8 CO’S NOTIFICATION ITEMS AS YOU CAN PER THE CO’S STANDING ORDERS? ARCOINST 1601.1Y

Back (Definition)

WHAT EQUIPMENT IS POWERED FROM 1E?

ASW, DEBALLAST PUMPS, SERVICE AND CONTROL AIR DRYERS, CAPSTAN, CHT, HALON ALARMS, HIGH TEMP/FLOODING SENSORS. COMM CKTS, LPACS, BILGE PUMPS, LIGHTING RCPTS, AIR LOCK SOLENOID VALVES, FO XFER PMP, VITAL VENTILATION, BALLAST CONTROL PANEL

DESCRIBE THE REQUIRED ACTIONS FOR A MISSING DANGER TAG? TUMS

STOP AFFECTED WORK


TAKE APPROPRIATE ACTION TO ENSURE CONTINUED PROTECTION OF PERSONNEL AND EQUIPMENT UNTIL REPLACEMENT TAG IS POSTED


A REPLACEMENT TAG TO BE FILLED OUT AND ADDED TO THE TORS


REVIEW THE ENTRIES ON THE REPLACEMENT TAG AND TORS FOR ACCURACY, COMPLETENESS

DESCRIBE THE CAPACITY AND POWER SUPPLY TO THE DEBALLAST PUMPS. ADDITIONALLY HOW MANY PUMPS CAN BE OPERATED ON DOCKS POWER EDG?

CAPACITY OF PUMPS 1,2,9,10 RATED AT 4900 GPM


CAPACITY OF PUMPS 3-8 ARE 5626 GPM


ALL PUMPS ARE POWERED FROM 1E


WHEN UNDER EDG POWER ONLY 6 PUMPS CAN RUN AT A TIME DUE TO INTERLOCKS

AT WHAT PRESSURE DOES THE ?CONTROL AIR LOW PRESSURE ALARM” AND “LOW SERVICE AIR” SOUNDS? WHERE DOES THIS ALARM SOUND?

LOW SERVICE AIR - 90PSI IN BALL CONTROL AND DOCKING


LOW CONTROL AIR -80PSI IN BALL CONTROL AND DOCKING

LIST THE DOCKS LIMITS FOR:


LIST AND TRIM AT ANY TIME?


NAVSEA APPROVED LIFTING CAPACITY?


WIND CURRENT AND VISIBILITY FOR DOCK AND UNDOCKING?


TANK LEVEL DIFFIRENTIAL LIMITS?


TANK LEVEL TO OUTSIDE DRAFT DIFFIRENTIAL?


DOCK DEFLECTIONS LIMITS?

Back (Definition)