How much brake horsepower (BHP) are the GTM's capable of producing?

26,250 BHP

Where are the GTM's located?

1A and 1B located in MER1 driving the starboard shaft



2A and 2B located in MER2 driving the port shaft

The Gas Generator consists of how many major assemblies? List.

4



1) 16-stage, axial flow Compressor


2) Annular type Combustor


3) 2-stage High Pressure Turbine (HPT)


4) Accessory Gearbox (AGB)

Where are the generator cooling fan motor controllers?

SSGTG 1 & 3- Located on the opposite side of the FADC



SSGTG 2- Located in the same side as the FADC

Where are the generator BID panels?

AUX 1- top level by the EEBD by ladderwell



MER2- By #4 UCC



3GTG- Port side entrance



Where are the generator emergency cooling controllers?

AUX 1- bottom level by where we TBR



MER2- bottom level by 2B Lube oil service pump controller



3GTG- Bottom level beside the fuel service heater

Where are the generator MORPAC firemain backup valves?

AUX 1-Bottom level beside the rag bin



MER2- Top level over 2A GTM



3 GEN- Bottom level by fire pump 6 controller

Where are the generator firemain backup SOPV's?

AUX 1- Bottom level beside the rag bin



MER2- Top level over 2A GTM



3 GEN- Bottom level by fire pump 6 controller

Where are the generator sea water cooling pump breakers?

AUX 1- On the back of 1SG



MER2- On the back of 2SG



3GTG- On the back of 3SG

Where are the generator sea water Hellan strainers?

AUX 1- Bottom level by the eductor



MER2- Bottom level by the big sink



3 GEN- Bottom level beside fire pump 6

During a generator start, what are u checking for the visual inspection?

FOD



Lube oil



BID



Dampers



DVRS (Digital Voltage Regulator System)



Sight flow

What type of oil does the generator use?

23699 synthetic lube oil

What is the sump size for the generator? What is the sump size for the GTG?

14 gal sump


75 gal sump

A slow start will automatically shut down the GTG (T or F)

True

What procedure is used to align the GTG?

GTSS

During a Class B fire situation in a generator module, if the primary halon is ineffective. Can the time delay be bypassed for Reserve halon?

Yes

What is the max effective range for a PKP, CO2, and AFFF bottle?

PKP



CO2- 4-6ft



AFFF

What are the symptoms and actions of a PSDF (Post Shutdown Fire) on the RIMSS? GTG?

RIMMS


Symptoms is high TIT (Turbine Inlet Temp)



Actions= Trip fuel-put in local-bleed air-motor (motor until temp goes below 750°F



GTG



Symptoms- High TIT



Actions=Trip fuel-put in local-bleed air-motor (motor until temp goes below 400°F


How often must LOFSP samples be taken? Name all instances.

30 min then every 4 hours

Why should the HOPM (Hydraulic Oil Power Module) bypass valve be open prior to start up of the CRP (Control Reversible Propeller Pitch) system?

To release the pressure

What is the purpose of the CRP head tank?

Maintains a static head pressure preventing seawater from leaking past the blade seals into the system

Where are the LP air priority valves located?

In front of the LP air compressor tank

What is the rating of the FOSP (Fuel Oil Service Pump) in slow and high speed?

Slow speed- 36 GPM @ 105 PSI



High speed- 72 GPM @ 105 PSI

Explain the F/O logics.

When the FOSP is at slow and drops below 20 PSI, lead and standby pumps will kick into fast speed for 5 seconds...if it doesn't go back to normal psi then logics will command the lead pump to stop (assuming there is a leak)

High DP for F/O Coalescer (separator)? High DP for F/O prefilter?

Coalescer is 15 PSI


Prefilter is 18 PSI

At what pressure does the priority valve close? List three air sources that get secured when the valve is shut.

Closes at 85 PSI



Service outlets, F/O purifiers, L/O purifiers

What is the alarm set point for high DP on the Prefilter? What is the alarm set point for high DP on the coalescer?

Prefilter 18 psi


Coalescer 15 psi

What is the rating for the SWSP? What is the location of each of these?

1575 gpm @ 35psi



MER1/2


AUX1/2


SHAFT ALLEY


List three systems that use vital LP air?

Blow in Door, ventilation closures, vent dampers

With a loss of LP air, what position does the F/O pressure regulator valve fall at?

Fail shut- to stop fuel from going through into the system in case of casualty

What are the two ways to inflate the stern tubes? After inflation are u able to rotate the shaft?

LP air and CO2



No

What is the purpose of conducting a fuel purge? When is it required?

To flush out cold fuel



What is the normal operating temperature range of a line shaft bearing?

125 °F +5 -5

Why do you need the lube oil system operating prior to starting a GTM?

To lubricate and keep it cool

How many AFFF reels are in MER2?

4

What can cause high VIBS on a GTG? What is an indication of high VIBS?

FOD, compressor stall, dirty blades



What does LOFSP stand for?

Lube Oil Filter Separator Purifier

How do u align an eductor?

IAW ED



Discharge, firemain, suction

What is the difference between type I and type II dehydrator?

Chill water and desiccant chambers

What do you align the stern tube IAW? What is the normal pressure and flow rate of the stern tube?

STCW



Flow rate is 15-20psi

How do u place the OD box in manual? How do u check for positive pitch control?

By moving the change over valve to manual



By using the manual joystick +5 and -5

Explain the L/O logics.

-Normal L/O header pressure is 14.5 psi



-if pressure drops to 13psi, lead pump cycles to "slow"



-if pressure drops to 11.5psi, lead pump cycles to "fast"



-if pressure drops to 10psi, standby pump cycles to "fast"



-the operator must stop manually. They will not stop automatically in the event of loss L/O pressure

What is the purpose of the unloader valve for the F/O system?

To maintain pressure

What must be aligned prior to starting the first LOSP in each MER?

Electric perciportator

Describe the locations for all the manual F/O quick trips.

AUX1- 1st deck across from CIC



MER1- 1st deck by ladderwell to MER1



MER2- under the fresh water hose reel by CCS



3GEN- Beside the starboard side entrance

What PMS documents do you follow for drawing L/O samples?

MIP 2411


R-20D

What is the rating of the LOSP (Lube Oil Service Pump)?

Electric


Slow 318 gpm @ 100psi


Fast 560 gpm @ 100 psi



Attached


693 gpm @ 168 SRPM and 75psi


What are your immediate actions for a class bravo fire in a GTG module?

Report manned



Operate the affected GTG emergency fuel trip and shut manual



Make sure GTG damper is shut



Put GTG LOCOP in local



Visually inspect the GTG through the window



Report to EOOW of actions done



Man AFFF



Report to EOOW fire is out. Reflash watch is set

What is the purpose of the No Brake Power Supply?

Supplies 30 min of back up power for the GTG



Basically it's like an UPS (Uninterrupted Power Supply)

What is the first step in combating a class C fire?

Report to EOOW and man Repair Electrician on scene

Describe your immediate actions when combating major flooding in 3 Gen.

Report


Isolate


Deflect

What are the steps for donning an EEBD?

Make sure gauge is in the green



Make sure ball bearing is still attached



Look at life date



Remove neck strap



Insert mouthpiece



Nose clip



Inhale through mouth

Summarize the steps for water washing a GTG.

Tagout



Disconnect the sensing lines



Open inlet and outlet drains



Put the configuration in the FADC for water wash



Wash then rinse



Motor



Restore



Draw the L/O system for MER2.

-

Draw the F/O system for MER2.

-

What equipment is used to stabilize sagging bulkheads/overheads?

Shoring

What is the sump size for LSB (Line Shaft Bearing)? What is the type of oil?

38 gal


Oil type 2190

When taking a L/O PPS (ie. Storage tank), what is the information you write on the bottle?

Date


Time


Signature

Where is the fuel valves for NR 1 GTG and RIMMS?

Bottom level AUX 1 over top of the eductor

What procedure do you use to motor the GTG?

GTMS

What components cool the GTG L/O system?

Sea water or firemain

What is the PMS doc of water washing the RIMSS (Redundant Independent Mechanical Start System)?

MIP 3113


R-26

When are L/O samples taken on the MRG while in operation?

Daily

What are the readings taken on the GTG each hour?

BID


SW pump discharge pressure


SW pump suction pressure


SW strainer DP


Generator L/O sump level


Gearbox sump level

What are the required readings for the thrust bearing?

Sight flow


Pressure


Temperature

With a complete loss of shipboard air, what position does the F/O and L/O unloader valve fall in?

F/O valve will fail shut to stop fuel



L/O valve will fail open to continue flow to the system and bearings

What type of oil does the GTG use?

23699 synthetic oil

How do you prime LOSP (Lube Oil Service Pump) during the start up of the first pump?

You align LOFSP (Lube Oil Filter separator Purifier) then prime it IAW LOSRG

What is the parameter for the BID?

For GTG its 9.5 inches of water


For GTM its 8.5 inches of water

What could possibly happen to the GTG if the BID opens while the GTG is running?

Debris or FOD will have easy access to the GTG because of no filter from BID

What valve do you open or shut during start up or stopping of NR3 GTG?

GSW-V-072

Describe your actions as a PSM during a major fuel leak and then a main space Class B fire.

Report


Shut fuel


Put FADC in local


Start halon or AFFF