Automatic Main Feed Pump Trips

1. Rx Trip


2. SI


3. Overspeed (107%)


4. IOPS (110%)


5. Thrust bearing wear


6. Low lube oil pressure (4# - 5 second time delay)


7. S/G water level Hi-Hi (P-14)


8. Low vacuum (20" Hg)


9. Low suction pressure (180# - 5 sec time delay)


10. Low trip header pressure (800#)

What flow rate do the MFP ELO's modulate to maintain?

4,000 gpm

By design the MFW system can handle a ____% step change or ___%/minute ramp load change without steam dumps.

10



5

Feedwater isolation (FWI) closes what valves?




Test Question - note if they provide a reactor trip only on one train.

Feed reg. valves (either train) FRV - 210, 240 (A) FRV-220, 230 (B)



Feed motor op isolation valves (train specific) FMO-201, 204 (A) FRV-202, 203 (B)

What is the FW mass flow rate to each steam generator?

3.55 million lbm/hr U1



3.7 million lbm/hr U2

The high pressure heater strings provide how much flow?

80%

The high pressure heater bypass (FMO-260) can handle how much flow?

20%

What position will the ELO's go if the stop valves are open and the control switch is taken to closed?

full open

The FW regulating valves are positioned by what other system?




What percent of steam flow are the FRVs placed in full service?

Steam Generator Water Level Control





25% steam flow

The MFW pumps take suction from which two sources?

Condensate System & Heater Drain Pumps

What inputs to the Feedwater Isolation (FWI) signal?




Test Question

1. SG water level HI HI (67%) - 2/3 on 1 SG.


2. SI


3. Rx. Trip with Low Tavg 545F (554F) - 2/4 loops

What will auto start the MFP seal water PP?

Booster pump discharge vs. MFP suction pressure < 15 psid.

The MFP Seal Water FRVs regulate on what input?




Test Question

Temperature - maintains seal water leak off temp at 150F.

Per TS 3.7.3 4 MFIVs and 4 MFRVs are required during which modes of operation?

1- 3 except when isolated.

The MFP discharge valves (FMO-251 & 252) close on what signal?

Close on MFIV closure (MFP Trip) - they do not close on a FWI.

FRVs close on a loss of what?

250 VDC and air

What impact to the MFPs will result from a loss of Circ Water?

MFW Pumps will trip due to loss of vacuum.

What impact to the MFPs will result from a loss of Condensate?

MFW pumps will trip due to loss of low suction pressure.

What impact to the MFPs will result from a loss of NESW?

MFW pumps will trip due to loss of cooling to the LO system.

What is the source of steam to the MFP Turbines at 30% power?




70% power?




Test Question

30% - Main Steam




55 - 60% - Reheat Steam (preferred)

CRV-224 will auto open based on what input to the MFW Pumps?




Test Question

Low MFP suction PRESSURE at CPC-224, located past #4 heaters just before the MFW Pumps.