- Front
- Back
What is the preferred pH for detergents used for most cleaning processes? |
Neutral pH |
|
Which of the following is an example of regulated medical waste? |
Blood-soaked sponges |
|
Which of the following statements about the use of mechanical washers is NOT true? |
All items should be washed on the same cycle |
|
Water must be degraded each time the ultrasonic cleaners tank is changed, because: |
Excess bubbles from filling reduce the energy of the cavitation process |
|
Specialized clothing or equipment worn by an employee for protection against hazard is called: |
PPE |
|
Written cleaning instructions for surgical instruments should be provided by: |
The instrument manufacturer |
|
Pyrogens: |
Are fever-producing substances |
|
Softened water: |
Decreases the likelihood of mineral scale deposits |
|
The desired solution for cleaning instruments is: |
A detergent |
|
These are used to breakdown fatty tissue on instruments: |
Lipase enzymes |
|
Instrument lubrication is performed: |
After cleaning |
|
To prevent coagulation of proteins, water temperature should be: |
Below 40'c (110'f) |
|
Detergents used in mechanical cleaners should be: |
Low foaming |
|
Aluminum items should be cleaned: |
Using a to and fro motion with the grain |
|
Powered surgical instruments: |
Can not be immersed |
|
The use of heat to kill all microorganisms, except spores, is called:
|
Thermal disinfection
|
|
These chemicals are used in animate(living tissue) to slow the growth of microorganisms:
|
Antiseptics
|
|
Items that are introduced directly into the bloodstream or other normally sterile areas of the body are classified as:
|
Critical
|
|
The process by which all forms of microorganisms are completely destroyed is called:
|
Sterilization
|
|
Iodophors are a member of this disinfectant family:
|
Halogens
|
|
Phenolics are classified as:
|
Intermediate to low–level disinfectants
|
|
Which of the following are classified as high–level disinfectants:
|
Gluteraldhyde and OPA
|
|
Thermal disinfection is accomplished using:
|
Heated water
|
|
How long must alcohol remain in wet contact with an item to achieve a reasonable level of disinfection?
|
5 minutes
|
|
Which of the following would be the best choice for high level disinfection if instruments?
|
OPA
|
|
Items need to be cleaned before they are sterilized, but they do not need to be cleaned before they are disinfected.
|
False
|
|
When liquid chemicals are labeled as both a high–level disinfectant and a sterilant, the time required to achieve sterilization is longer than the time required to achieve high–level disinfection.
|
True
|
|
Mechanical washers and washer–decontaminators are regulated by the CDC.
|
False
|
|
All liquid disinfectants are capable of sterilization if their exposure time is increased.
|
False
|
|
Log books should be maintained when using gluteraldehyde and OPA.
|
True
|
|
Micro grind, or super cut scissors are usually identified with a black handle.
|
True
|
|
Stainless steel jaw needle holders last longer than tungsten carbide jaw needle holders.
|
False
|
|
The place where the two parts of a ring handle instrument meet and pivot is called a box lock.
|
True
|
|
Instruments are heat treated to give their surface a mirror(shiny) finish.
|
False
|
|
Tissue forceps have teeth
|
True
|
|
During instrument manufacture the process of passivation helps build a protective chromium oxide layer on each instruments surface.
|
True
|
|
The part of a hemostat that locks and holds it in position is called a box lock.
|
False
|
|
Laser–finished instruments are coated with a durable protective finish that cannot be chipped or scratched.
|
False
|
|
When assembling an instrument set, heavier instruments should be placed on top of the lighter ones to hold them in place.
|
False
|
|
After applying instrument identification tape, instruments should be autoclave to help the tape bond to the instrument.
|
True
|
|
Instrument marking tape should be wrapped approximately _______ around the instrument.
|
1 to 1 1/2
|
|
Which of the following is NOT an acceptable form of instrument marking?
|
Electric etching(engraving)
|
|
The purpose of a suction stylet is to:
|
Unclog the suction during surgery
|
|
Kerrison laminectomy ronguers should be tested using:
|
Index card
|
|
Scissors with tungsten carbide cutting edges are usually identified by:
|
Gold handles
|
|
The first step to inspect the insulation of a laparoscopic instrument is to:
|
Check the collar at the distal tip
|
|
Which of the following steps happens first when processing flexible endoscopes?
|
Leak–test
|
|
Which of the following should be used to thoroughly rinse(remove) all traces of disinfectant from an endoscope channels?
|
Filtered water
|
|
The purpose of using a decontamination battery or cord when cleaning powered surgical instruments is:
|
To keep fluid from entering a unit
|
|
Endoscopes are often processed in a mechanical washer unit called:
|
Automatic endoscope reprocessor
|
|
The endoscope that would be dispensed for a procedure that required visualization of the lower part of the large intestine would be a:
|
Sigmoidoscope
|
|
Loaner instruments should be:
|
Be decontaminated before use
|
|
Information regarding cleaning processes for endoscopes should be provided by:
|
The instrument manufacturer
|
|
Which of the following statements about endoscopes is true?
|
Not all endoscopes can be processed in an AER
|
|
Electronic testing of laparoscopic insulation should be done:
|
In the clean assembly area prior to set assembly
|
|
Loaner instrument poses storage and workload challenges.
|
True
|
|
Loaner instrument poses storage and workload challenges.
|
True
|
|
Flexible endoscopes that fail leak test may continue to be used until the break/hole impacts the scope's function.
|
False
|
|
All flexible endoscopes have internal channels.
|
False
|
|
After use, loaner instrumentation must be decontaminated before its is shipped out.
|
True
|
|
The biggest advantage to battery–powered surgical instruments is that they can be immersed for cleaning.
|
False
|