How often should system maintenance be performed on the Husky-12?
20 hrs of foam system operation
Where is the manual flush drain valve located for the Husky-12 foam system?
Under the driver side running board
What maintenance should be done when a system maintenance message is received on a Husky-12?
The foam and water stainers should be cleaned, and hydraulic oil changed.
How is the Husky-12 hydraulic system activated?
Automatically when the pump is engaged
What type of filter does the hydraulic system use?and where is it located?
Pressure bypass element-type filter located in the pump-house.
What type of hydraulic cooler does the husky-12 system use?
Oil-to-water type heat exchanger
How is the foam supply valve opened?
Automatically when the system is turned on.
Of What is the hydraulic end of the pump made? And the foam end?
Hydraulic- painted steel

Foam - brass
On the husky-12 hydraulic pump, which is the inlet line and which is the pressure line?
The larger line is the inlet from the tank and the smaller line is the pressure line that drives the foam pump.
What is the capacity of the hydraulic reservoir for the Husky-12?
Approx. 4 gallons
At what level do you receive a warning message for the level of the foam concentrate tank?
When the tank is below one quarter
What type of pump is used for the foam concentrate?
Double-acting cylinder pump
The foam pump has a capacity of ____GPM with all types of foam concentrate.
12
Can the foam pump draw foam from external sources such as drums or pails?
yes
Foam discharges can be identified by what?
Red and white discharge tags
What does the water supply system do?
Supplies water to the foam injection manifold for foam to be added and distributed.
What are the manifold drains used for?
To drain off water/pressure anytime the system is used.
The control head microprocessor monitors what two things to ensure the proportion rate is accurate?
-water flowmeter
-foam pump rate
How does the foam pump prime?
The pump is self priming
the external foam pick-up consist of What?
1-1”male connection w/ chrome cap integrated into a 2”strainer clean-out cap.
What is on the external supply hose to prevent water from backing up and contaminating the foam supply?
Foam check valve
What measure the flow of water supplied to the foam/water discharges before the foam is injected?
Water flow meter
How does the operator interface with the foam system
The foam system control head
If the foam system is turned off, the display functions as a what?
flowmeter
What is the default foam setting on the Husky-12 system?
Class a @ 0.3-5%
What automatically occurs when switching from class a foam to class b foam, From tank or draft?
An automatic 15 sec. flush
When is the prime mode used?
After filling the foam tanks to purge air or to fill the suction hose for drafting the foam.
How do you begin to clean out the system after you have drafted both Class A or B foam?
By drafting clean water through the suction hose
How are the control head screens zeroed on scene?
By push the up and down arrows at the same time and releasing.
What are the 6 steps to activating the Husky-12 in class A mode w/ an on board tank?
1. Engage water pump transmission
2. Recirculate water
3. Turn the system on
4. Begin flowing water, foam pump will activate.
5. use the arrow up/down buttons to change percentage.
6. when beginning the mop up phase, turn the system off; use the foam in the hose for mop up.
What must be done for the automatic flush to work properly?
A foam discharge or manifold drain must be open during the flush to give the solution somewhere to go.
What button do you push to change the system over to draft Class B?
By pushing the mode button until draft class b appears on the screen
What are the 6 steps to using the priming system on the foam pump?
1. Select the foam source.
2. Open the manifold drain ¼ turn
3. After the change over is complete, press mode until the prime mode screen appears, then enter.
4. Press and hold the enter button(a 2nd time). This will run the foam pump at 7gpm until the button is released.
5. Release the button when foam is discharged out of the manifold drain.
6. Allow water/foam solution to run out of the manifold drain until it is mostly clear of foam if unit is not immediately going to be
In manual mode why must one discharge be open?
If at least one discharge isn’t open the foam pump could charge the lines up to 300psi.
In manual mode, the ____ flow rate will remain constant, even when actual _____ flow fluctuates.
Foam; water
Who should use the calibrate and setup modes?
Should only be used by qualified personnel because these can adversely affect the system performance.
Why should the foam system be periodically operated?
To insure the system is operational and circulate the foam concentrate through the system.
Should the water strainer be cleaned and inspected weekly or quarterly?
weekly
Why must class a and class b foams not be mixed in the system?
It can cause a chemical reaction creating globules that can clog orifices and cause system failure.
When is the only time use flowmeter will appear on the screen?
By pressing the mode button when in manual mode.
When in manual mode what returns the system to (normal) flowmeter control?
Pressing mode until use flowmeter appears and pressing enter.
Why must inspections and maintenance be done according to pierce manufacturing standards?
Failure to comply with requirements will be considered grounds or conditions that may void the warranty.
Should the foam strainer be cleaned and inspected weekly or quarterly?
quarterly
How do you know if the hydraulic oil tank is filled to the proper level?
The glass sight gauge should be ¾ full.
How do you know if it is time to change the hydraulic oil in the Husky-12 system?
Compare it to previous samples and if degraded it needs to be changed.
What prevents foam from entering the water pump and the remaining of the water system?
In-line water check valve
How often should the water pump drain be pulled?
daily
On a pump rating of 250 psi, what percentage of foam solution can be delivered at 200gpm?
6%
What should be checked on the annual inspection of the hydraulic system of the Husky-12?
The hydraulic oil
What type of hydraulic oil is recommended for use ?
ISO 68 or equivalent.
What controls the correct valves and directs the hydraulic fluid in order to get the proper injection rate of the foam?
controller module
What valve controls whether the foam tank is getting filled or its going into the injection system?
Foam selector valve
On a pump rating of 250 psi, what percentage of foam solution can be delivered at 4000gpm?
0.3%