• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/7

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

7 Cards in this Set

  • Front
  • Back

What permissives does battle override bypass?

PT speed limiting


PT torque limiting


PLA actuator system failure


Lube scavenge temp high shutdown


300 rpm system reset latch out


Fuel shutoff valve current monitoring


GG speed step to idle on high vibration



What does ECM mode selector do?

Sets the GT operating mode to automatic or auxiliary

What conditions indicate icing?

Below 5°C and above 70% humidity

What are the vibration parameters?

GG max alarm - 4 mm


GG max step to idle - 7mm


PT max alarm - 7mm


PT max step to idle 10mm

What will cause ESTOP OF GT? (Start up)

NGG failed to reach 1200 in 20 seconds



T5.4 failed to reach 204°C in 40 seconds of ignition



NGG failed to reach 4500 in 90 seconds



What causes ESTOP OF GT? (Running)

Flame out <204 deg



T5.4 @ 918 deg+/-5



Fuel manifold pressure <12 bar for 10 seconds



Fuel shutoff valves under/over current



GLOSS CCGB pressure <0.5 bar instantly (<1 bar 15 seconds)



LOSCA pressure < 0.42 bar instantly (<1 bar in 5 seconds)



Scavenge oil temp > 170 deg



PT overspend 3960 +/- 40 rpm



PT loss of speed signal (A+B channel)



ECM failure

What does the shutdown interlock bypass?

In the event of failure to light off (when T5.4 fails to reach 200 deg during a start)



Low oil supply pressure (less than 0.42 bar)



High pressure turbine inlet temp (T5.4 reaches 918 deg)