WHAT ARE 4 WAYS TO ACTIVATE THE APC SYSTEM?
|
-REMOVE CONTROL BOX-PRESSURE RELEASE CONTROL BOX-LEVER ON APC BOTTLE-LINK MELTS @ 360 DEGREES F
|
|
HOW MANY DEBALLASTING AIR COMPRESSORS ARE ON BOARD?
|
10 TOTAL ON BOARD
|
|
WHAT DO THE DEBALASTING AIR COMPRESSORS DO?
|
PROVIDE 7 TO 20 PSI OF HIGH VOLUME AIR THAT PRESSURIZES TANKS TO PUSH WATER OUT OF SEA CHEST VALVES
|
|
HOW MANY SEWAGE EJECTOR PUMPS ARE ON BOARD?
|
6 TOTAL
|
|
WHAT ARE THE TYPES OF SEWAGE EJECTOR PUMPS?
|
EDDY PUMPS & MACERATOR PUMPS
|
|
WHERE ARE THE SEWAGE EJECTOR PUMPS LOCATED?
|
2 EDDY PUMPS FOR FWD TANK2 EDDY PUMPS FOR AFT TANK2 MACERATOR PUMPS FOR SEWAGE & RECEIVING
|
|
WHAT IS THE M256A1?
|
A MAN-PORTABLE DETECTION KIT TO DETECT NERVE, BLISTER AND BLOOD AGENTS
|
|
WHAT EQUIPMENT IS USED TO CLEAN CHT SPILLS?
|
-POOPY SUITS-CHEMICAL GLOVES-FIREFIGHTING BOOTS-BANIDINE SANITIZER
|
|
WHAT ARE EFFECTS OF BLOOD AGENTS?
|
CASUALTY AGENT THAT EFFETCTS THE TRANSFER OF OXYGEM FROM BLOOD CELLS
|
|
WHAT ARE THE 4 PRINCIPLES OF INVESTIGATION?
|
CAUTIOUS
THOROUGH REPORT REPEAT |
|
WHAT DOES CMWD STAND FOR?
|
COUNTER MEASURE WASH DOWN
|
|
WHAT IS THE PURPOSE OF THE CMWD?
|
TOTAL OUTSIDE SURFACE COVERAGE WASH TO CLEAR AWAY SOLID AND LIQUID CHEMICAL AND BIOLOGICAL THREATS
|
|
HOW MANY ZONES ARE IN THE CMWD?
|
12 ZONES
|
|
WHAT IS SPECIAL ABOUT CMWD ZONES 2 AND 3?
|
COVERS THE TOPS OF SUPER STRUCTURES
|
|
WHAT IS IPDS?
|
AN INSTALLED VAPOR SYSTEM SENSOR THAT DETECTS NERVE AND BLISTER AGENTS
|
|
WHAT IS JBPDS?
|
AN INSTALLED AUTOMATIC DETECTOR THAT DETECTS BIOLOGICAL AGENTS IN REAL TIME
|
|
WHAT ARE THE CAPACITY OF THE CHT TANKS?
|
FWD 26,162 GALLONS
AFT 27,496 GALLONS SEWAGE AND RECEIVING 295 GALLONS |
|
WHAT DOES ACPG STAND FOR?
|
ADVANCED CHEMICAL PROTECTIVE OUTER GARMENT
|
|
WHAT IS THE PURPOSE OF THE ACPG?
|
TO PROTECT FROM CBRN HAZARDS
|
|
WHAT IS THE ACPG MADE OUT OF?
|
NYLON COTTON POPLIN OUTER SHELL
|
|
HOW MANY AFFF SPRINKLER GROUPS AND ZONES?
|
30 SPRINKLER GROUPS (INTERNAL)
12 SPRINKLER ZONES (FLIGHT DECK) |
|
WHAT IS THE CLASSIFICATION FOR BETA RADIATION?
|
CAN TRAVEL 10 FEET
UNIFORM IS SUFFICIENT PROTECTION CANNOT PENETRATE THE SHIP’S HULL |
|
HOW MANY MAIN AND SECONDARY DRAINAGE EDUCTORS ARE ON BOARD?
|
7 MAIN DRAINAGE EDUCTORS
19 SECONDARY DRAINAGE EDUCTORS |
|
HOW MANY GALLONS DOES EACH AFFF STATION HOLD?
|
2000 GALLONS
|
|
WHAT IS THE PURPOSE OF RADIACS?
|
USED TO DETECT AND/OR MEASURE THE PRESENCE OF RADIATION
|
|
PURPOSE OF THE AN/PDQ-1 (IM-265)
|
A PORTABLE MONITORING DEVICE THAT DETECTS RADIATION
|
|
WHAT IS THE CLASSIFICATION OF NEUTRON RADIATION?
|
CAN TRAVEL THOUSANDS OF YARDSWILL PENETRATE SHIP’S HULLUNIFORM DOES NOT PROTECTEXTERNAL HAZARD AFTER 1ST MINUTE AFTER BURST
|
|
WHAT IS THE DIFFERENCE BETWEEN PATHOGENS AND TOXINS?
|
PATHOGENS ARE MICROBES THAT CAUSE DISEASESTOXINS ARE SUBSTINCES PRODUCED BY ORGANISMS THAT ARE HARMFUL TO HUMANS
|
|
WHAT DOES CBRN STAND FOR?
|
CHEMICAL BIOLOGICAL RADIOLOGICAL NEUCLEAR
|
|
HOW MANY AFFF STATIONS ARE ONBOARD?
|
6 TOTAL
|
|
WHAT IS THE PURPOSE OF THE HPUS?
|
PROVIDE HYDRAULIC POWER FOR THE SEA CHEST VALVES
|
|
AT WHAT LEVEL OF PSI DO THE HPUS OPERATE AT?
|
350 TO 700 PSI
|
|
WHAT ARE THE 4 TYPES OF RADIATION?
|
ALPHA
BETA GAMMA NEUTRON |
|
WHERE ARE APC SYSTEMS LOCATED ON THE SHIP?
|
CREW GALLEY
CPO GALLEY WARDROOM GALLEY FLAG GALLEY CO’S GALLEY BAKE SHOP |
|
WHAT ARE THE CPS BOUNDRIES?
|
ZONE 1-FRAMES 1-33
ZONE 2-FRAMES 33-49 ZONE 3- FLIGHT DECK TRIAGE ZONE 4-CIC ZONE 5-MEDICAL AND TROOP BERTHING ZONE 6-REST OF MEDICAL |
|
WHAT ARE THE EFFECTS OF NERVE AGENTS?
|
DISRUPTS THE TRANSMISSION OF NERVE IMPULSES
|
|
WHAT DOES APC STAND FOR?
|
AQUEOUS POTASSIUM CARBONATE
|
|
WHAT ARE DRAFT MARKINGS?
|
NUMBERS ON THE OUTSIDE SKIN OF THE SHIP THAT SHOWS HOW DEEP THE SHIP IS IN FEETNUMBERS ARE 6 INCHES TALL, 6 INCHES APART
|
|
WHAT IS THE HALON SYSTEM ACTUATED BY?
|
5 IB CO2
|
|
WHAT DOES MOPP STAND FOR
|
MISSION ORIENTED PROTECTIVE POSTURE
|
|
WHAT IS CLASSIFIED AS BLACK WATER?
|
WATER FROM COMMODES AND URINALS
|
|
WHAT ARE AFFF STATION TANKS MADE OF?
|
90% COPPER
10% NICKEL |
|
WHERE ARE THE FIRE PUMPS LOCATED?
|
1,2,3 AND 4= FWD FIRE PUMP ROOM
5 AND 6= FWD MMR 7 AND 8= AFT MMR 9,10,11 AND 12= AFT FIRE PUMP ROOM |
|
WHAT ARE THE PUMP RATES OF THE FIRE PUMPS?
|
FWD AND AFT FIRE PUMP ROOM= 1000 GPMFWD AND AFT MMR= 2000 GPM
|
|
WHAT ARE THE EFFECTS OF BLISTER AGENTS?
|
CAUSES DAMAGE TO THE BODY TISSUE AND SEVERE PAIN
|
|
WHAT ARE EFFECTS OF TEAR AGENTS?
|
INCAPACITATES BY IRRITATING THE EYES
|
|
HOW MANY KITS ARE IN THE M256A1?
|
12 INDIVIDUALLY PACKED KITS
|
|
WHAT ARE EFFECTS OF CHOKING AGENTS?
|
CASUALTY AGENT THAT EFFECTS BREATHING AND EFFECTIVENESS OF THE LUNGS
|
|
WHAT ARE EFFECTS OF VOMITING AGENTS?
|
USED TO INCAPACITATE WITH SEVERE VOMITING
|
|
WHAT DOES CHT STAND FOR?
|
COLLECTION, HOLDING AND TRANSFER
|
|
HOW MANY REPAIR LOCKERS DOES WASP HAVE? HOW MANY ARE USED?
|
10 TOTAL ON BOARD, ONLY 8 ARE USED
|
|
WHAT ARE THE TWO TYPES OF WASTE WATER?
|
BLACK WATER- SOIL DRAIN
GREY WATER- WASTE DRAIN |
|
WHAT DOES JBPDS STAND FOR?
|
JOINT BIOLOGICAL POINT DETECTION SYSTEM
|
|
WHERE WOULD YOU FIND AN APC SYSTEM ATTACHED TO?
|
DEEP FAT FRYERS AND DONUT FRYERS
|
|
WHAT IS THE PURPOSE OF THE SHORE CONNECTION RISERS?
|
USED TO CONNECT HOSES FROM THE SHIP, TO SHORE FACILITIES TO PUMP WASTE WHILE IN PORT
|
|
WHO CANNOT USE THE M256A1
|
COLOR BLIND PERSONNEL
|
|
HOW MANY SHORE CONNECTION RISERS ARE THERE? WHERE?
|
4 TOTAL
2 PORT 2 STBD |
|
WHAT TYPE OF FIRE MAIN IS USED ON WASP?
|
SINGLE LINE, SINGLE LOOP COMPOSITE
|
|
WHAT ARE THE 3 TYPES OF TANKS?
|
ABOVE WATER LINE TANKS
PARTIALLY ABOVE WATER LINE TANKS BELOW WATER LINE TANKS |
|
WHAT ARE THE 3 MODES OF OPERATIONS FOR WASTE?
|
IN PORT- SHORE SERVICES
TRANSIT- HELD IN TANKS AT SEA- 3 NAUTICAL MILES AWAY FROM SHORE, DUMPED OVERBOARD |
|
WHERE ARE THE 3 PLACES THE CMWD CAN BE ACTUATED, AND BY WHO?
|
DAMAGE CONTROL CENTRAL= DCABRIDGE= NAVIGATORPRIMARY FLIGHT CONTROL= AIR BOSS
|
|
WHAT IS M8/M9 PAPER?
|
CHEMICALLY TREATED PAPER THAT DETECTS LIQUID NERVE AND BLISTER AGENTS
|
|
WHAT ARE BATTLE DRESSING STATIONS?
|
READY MADE COMPARTMENTS, PLACED STRATEGICALLY THROUGHOUT THE SHIP, FOR QUICK ACCESS TO WOUNDED PERSONNEL
|
|
HOW MANY SPACES ARE PROTECTED BY HALON?WHAT TYPES?
|
15 SPACES TOTAL60 SECOND AND 30 SECOND TIMER DELAY TYPES
|
|
HOW DO ABOVE WATER LINE TANKS OPERATE?
|
FILLED WITH FIRE MAINDRAINED BY HYDRAULICALLY OPERATED SEA CHEST VALVES
|
|
HOW LONG CAN THE ACPG LAST IN A CONTAMINATED ENVIRONMENT, NON CONTAMINATED ENVIRONMENT AND WHEN SEALED?
|
24 HOURS IN A CONTAMINATED ENVIRONMENT45 DAYS IN A NON-CONTAMINATED ENVIRONMENT5 YEARS IN THE SEALED BAG
|
|
WHAT SPACES ARE PROTECTED BY THE 60 SECOND TIME DELAY HALON SYSTEM?
|
FWD MMR
AFT MMR AUX MMR CARGO HOLD 10 |
|
HOW DO BELOW WATER LINE TANKS OPERATE?
|
FILLED BY SEA CHEST VALVESDRAINED BY SEA CHEST VALVES AND LOW PRESSURE, HIGH VOLUME AIR
|
|
WHAT MASK AND CANISTER DOES WASP USE? HOW MANY/WHAT TYPE OF THREADS ON THE CANISTER?
|
WASP USES THE MCU-2P MASL, C-2 CANISTER AND HAS 3 NATO STANDARD THREADS
|
|
WHAT IS THE CLASSIFICATION OF ALPHA RADIATION?
|
RANGE OF 0-2 INCHES
CANNOT PENETRATE HUMAN SKIN INTERNAL HAZARD ONLY |
|
WHERE ARE THE 3 TANKS USED FOR CHT?
|
FWD 6-37-0-W
AFT 5.5-73-1-W SEWAGE & RECEIVING 3-113-6-W |
|
WHAT ARE HAZARDS OF CHT?
|
FLOODING
HYDROGEN SULFIDE GAS(H2S) |
|
WHERE ARE THE MAIN DRAINAGE EDUCTORS LOCATED?
|
2 IN FWD MMR
2 IN FWD JP5 3 IN AFT MMR |
|
WHAT DOES CPS STAND FOR?
|
COLLECTION PROTECTION SYSTEM
|
|
WHAT DOES SEWAGE AND RECEIVING DO?
|
COLLECTS AND TRANSFERS ONLY
CANNOT PUMP OVERBOARD |
|
WHERE ARE THE DEBALLASTING AIR COMPRESSORS LOCATED?
|
2 IN FWD DEBALLAST AIR COMPRESSOR ROOM
5 IN AMR 3 IN AFT DEBALLAST AIR COMPRESSOR ROOM |
|
HOW MANY AND WHAT INJECTORS ARE GIVEN FOR A NERVE AGENT ATTACK?
|
3 ATROPINE AUTO-INJECTORS
3 2-PAM CHLORIDE AUTO-INJECTORS |
|
HOW MANY BALLASTING TANKS ARE LIST CONTROL TANKS?
|
8 |
|
HOW MANY BALLASTING TANKS ARE SUPPLEMENTARY TANKS?
|
20 |
|
HOW MANY BALLASTING TANKS ARE RAPID BALLAST TANKS?
|
6 |
|
WHAT ARE THE THREE TYPES OF BALLASTING TANKS?
|
RAPID BALLAST TANKS
LIST CONTROL TANKS SUPPLEMENTARY TANKS |
|
HOW MANY SALT WATER BALLASTING TANKS DO WE HAVE?
|
34 |
|
WHAT ARE 4 WAYS TO COMMUNICATED WITH REPAIR LOCKERS?
|
SOUND POWERED TELEPHONES
J-DIALS MESSENGER REPORTING TO THE LOCKER YOURSELF |
|
WHAT DOES CPS PROVIDE?
|
PROVIDES FILTERD AIR FOR A CBRN ENVIRONMENT
|
|
WHAT TYPE OF CHT SYSTEM DO WE HAVE ON WASP?
|
GRAVITY FED COLLECTION HOLDING AND TRANSFER SYSTEM
|
|
WHAT IS THE PUMP RATE OF AFFF STATIONS?
|
65 GPM |
|
WHAT IS CLASSIFIED AS GREY WATER?
|
DECK DRAINS, SINKS, SHOWERS, GALLEY/SCULLERY AND LAUNDRY TYPE WASTE WATER
|
|
WHAT IS THE PURPOSE OF THE M291 KIT?
|
DECONTAMINATES LIQUID CHEMICAL AGENTS FROM EXPOSED SKIN BY PHYSICAL REMOVAL, ABSORPTION AND NEUTRALIZATION
|
|
HOW DO PARTIALLY ABOVE WATER LINE TANKS OPERATE?
|
FILLED WITH FIRE MAIN BY SEA CHEST VALVESDRAINED BY SEA CHEST VALVES AND LOW PRESSURE, HIGH VOLUME AIR
|
|
WHAT DOES IPDS STAND FOR?
|
IMPROVED POINT DETECTION SYSTEM
|
|
WHAT IS THE CLASSIFICATION OF GAMMA RADIATION?
|
CAN TRAVEL THOUSANDS FO YARDS AND WILL PENETRATE THE SHIP’S HULLWHOLE BODY HAZARD
|
|
WHAT DOES HPU STAND FOR?
|
HYDRAULIC POWER UNIT
|
|
HOW MANY HPU ARE ON BOARD AND WHERE ARE THEY LOCATED?
|
2 TOTAL
LOCATED IN DC CENTRAL AND WELL DECK CONTROL |
|
HOW MANY AND WHAT TYPE OF FIRE PUMPS ARE ON BOARD?
|
12 SALT WATER FIRE PUMPS (ELECTRICAL)
|
|
WHAT MAKES UP AFFF?
|
94% WATER
6% AFFF CONCENTRATE |
|
HOW MANY DECON STATIONS ARE THERE? WHERE?
|
5 TOTAL#1 PORT SIDE OF GYM
#2 STBD SIDE OF 01 MARINE BIRTHING #3 FLIGHT DECK TRIAGE, 03 LEVEL #4 FWD OF HANGAR BAY, STBD SIDE #5 02 LEVEL AFT, PORT SIDE |
|
WHAT SPACES ARE PROTECTED BY THE 30 SECOND TIME DELAY HALON SYSTEM?
|
HAZMAT RECYCLING CENTER, FWD DIESEL, AFT DIESEL, FWD JP-5 PUMP ROOM, AFT JP-F PUMP ROOM, SHIP’S STORE FLAMMABLE LOCKER, AVIATION FLAMMABLE LOCKER, LCAC PUMP ROOM, PAINT MIXING & ISSUE ROOM, SUPPLY STORE ROOM, AVIATION FLAMMABLE STORE RM
|
|
WHAT DOES HALON GIVE OFF AT 900 DEGREES F
|
HYDROGEN BROMIDEFREE BROMINEHYDROGEN FLOURIDE
|
|
WHAT IS THE NORMAL STEAMING DRAFT?
|
25’ 6” FWD
26’ 0” AFT |
|
WHAT IS MAXIMUM BALLASTED DRAFT?
|
20’ 0” FWD
40’ 0” AFT |
|
WHAT AFFF SYSTEM DO WE HAVE ON BOARD?
|
BALANCED PRESSURE PROPORTIONING SYSTEM TYPE 2
(BAD PARENTING PROMOTES STUPID TEENAGERS) |
|
WHERE IS FWD BATTLE DRESSING STATION?
|
MAIN DECK, PORT SIDE, FWD
|
|
WHERE IS THE AFT BATTLE DRESSING STATION?
|
MAIN DECK, PORT SIDE, AFT HANGAR BAY
|
|
WHERE IS THE 03 LEVEL BATTLE DRESSING STATION?
|
FLIGHT DECK TRIAGE
|
|
WHERE IS THE MAIN BATTLE DRESSING STATION?
|
MEDICAL
|
|
WHAT ARE THE 8 REPAIR LOCKERS?
|
1H, 2F, 2M, 3, 4, 5M, 5A, 6/7F
|
|
WHERE IS LOCKER 4 LOCATED?
|
AFT OF PORT SIDE SCULLERY
|
|
WHERE IS LOCKER 5M LOCATED?
|
STBD SIDE OF MESS DECKS
|
|
WHERE IS LOCKER 2M LOCATED?
|
FWD OF POST OFFICE
|
|
WHERE IS LOCKER 2F LOCATED?
|
02 LEVEL, FWD OF GYM
|
|
WHERE IS LOCKER 3 LOCATED?
|
PORT SIDE, MID SECTION OF HANGAR BAY
|
|
WHERE IS LOCKER 1H LOCATED?
|
STBD SIDE, AFT OF HANGAR BAY
|
|
WHERE IS LOCKER 5A LOCATED?
|
PORT SIDE, AFT OF CO’S LADDERWELL
|
|
WHERE IS LOCKER 6/7F LOCATED?
|
STBD SIDE OF OFFICER COUNTRY
|
|
WHAT IS THE PURPOSE OF MOPP AND HOW MANY LEVELS?
|
LEVELS SET TO PROTECT PERSONNEL FROM CBRN
THREATS 5 LEVELS TOTAL |
|
WHAT OCCURES AT MOPP 1?
|
TEST ALL DETECTION AND MONITORING SYSTEMSINVENTORY ALL CBRN EQUIP/MEDICAL SUPPLIES AND NOTE SHORTAGESAT MINIMUM, ENFORCE MATERIAL CONDITION YOKE
|
|
WHAT OCCURES AT MOPP 2?
|
CARRY PROTECTIVE MASK AT ALL TIMESTEST CMWD, ALARMS AND ISSUE DOSIMETERSMATERIAN CONDITION MODIFIED ZEBRA ENFORCEM8/M9 PAPER POSTED BY EACH REPAIR LOCKERSHIP CREW TRAINED IN POSSIBLE SITUATION
|
|
WHAT OCCURES AT MOPP 3?
|
SET GENERAL QUARTERS & MAT COND ZEBRADON PERSONNEL PROTECTIVE SUIT, CARY GLOVES AND MASK WITH A NEW C-2 CANISTER INSTALLEDWARM UP RADIACSACTIVATE CMWD AND MONITOR M8/M9 PAPERDECON STATIONS SHALL BE ACTIVATED
|
|
WHAT OCCURES AT MOPP 4?
|
STOP BREATHINGDON MASK, DON HOOD/GLOVESCMWD SHALL RUN CONTINUOUSLYMAT COND CIRCLE WILLIAM SETMAX PERMISSABLE EXPOSURE LIMITS MONITOREDMANDATORY DRINKING WATER REGIMEN PLACED
|
|
WHAT OCCURES AT MOPP 0?
|
INSPECT, SIZE, FIT AND ISSUE IPE TO ALL PERSONNEL
|