Double-insulated/ungrounded tool

An electrical tool that is constructed so that the case is insulated from electrical energy. The case is made of a nonconductive material.


Fibrillation

Very rapid irregular contractions of the muscle fibers of the heart that result in the heartbeat and pulse going out of rythm with each other.

Grounded tool

An electrical tool with a three-prong plug at the end of its power cord or some other means to ensure that stray current travels to ground without passing through the body of the user. The ground plug is bonded to the conductive frame of the tool.

Ground fault circuit interrupter (GFCI)

A protective device that functions to de-energize a circuit or portion thereof within an established period of time when a current to ground exceeds some predetermined value. This value is less than that required to operate the overcurrent protective device of the supply circuit.

Polychlorinated biohenyls (PCBs)

Toxic chemicals that may be contained in liquids used to cool certain types of large transformers and capacitors.

The most life-threatening hazard on a construction site typpically include all of the following except ____.

Chemical burns

Falls, electric shock, being crushed by falling or flying object, or chemical burns.

If a person's heart begins to fibrillate due to an electric shock, the solution is to ____.

Have a qualified person use emergency defribillation equipment.

True or false? Low-voltage conductors rarely cause injuries.

False

Class 00 rubber gloves are used when working with voltages less than _____.

500 v. They are identified by their beige colored tag.

An important use of a hot stick is to ____

Replace fuses.

Which of these statements correctly describes a double-insulated power tool?

It is made entirely if plastic or other nonconducting material.

Which of the following applies in a lockout/tagout procedure?

Lockout/tagout devices are installed by every authorized employee involved in the work.

Only the supervisor can install lockout/tagout devices



If several employees are involved, the lockout/tagout equipment is applied only by the first employee to arrive at the disconnect.



Lockout/tagout devices applied by one employee can be removed by another employee as long as it can be verified thay the first employee has left for the day.



Lockout/tagout devices are installed by every authorized employee involved in the work.

True or false? The NEC provides requirements for safe electrical installations, while NFPA 70E provides guidance for establishing safe electrical workplaces.

True

What is proper distance from the feet of a straight ladder to the wall?

One-fourth the working height if the ladder.

What are the minimum and maximum distances in inches that a scaffold plank can extend beyond its end support?

6;12

All of the following are usually considered confined spaces except a ____.

3-ft trench

3-foot trench



Sewer



Pipeline



Manhole

The best way to protect yourself from solvent hazards is to ____.

Read and follow all instructions on the product's SDS/MSDS.

Asbestos was banned in____; therefore, you must assume that any facility constructed before ____ has asbestos in it.

1978; 1980 because it was still in the manufacturing pipeline for a while after it was banned.

True or false? You may throw vapor lamps out with regular trash as long as you wrap them carefully to avoid breakage.

False. Recycled. Test tubes must be packaged.

A PFAS anchorage point for a 6-foot lanyard must be able to hold ____.

5k lbs

CFR part 1910 covers the ____.

Covers the OSHA standards for general industry.

CFR part 1926 covers the ____

Covers the OSHA standards for the construction industry.

True or false? You should use a compressor for an air test on high-voltage gloves because it has more pressure and is much faster.

False

There are 6 classes of rubber protective equipment.


Class 00 (beige tag)


500 V



Class 0 (red tag)


1k V



Class 1 (white tag)


7.5k V



Class 2 (yellow tag)


17k V



Class 3 (green tag)


26.5k V



Class 4 (orange tag)


36k V

All conductors, buses, and connections should be considered _____ until proven otherwise.

Live/hot/powered

The distance from the ladder feet to the base of the wall should be about ____ the vertical distance from the bottom to the top of the ladder.

1/4

As it is erected, each parth of a scaffolding shall be carefully _____

Inspected

List the general guidelines used in identifying a confined space.

Has limited entry and exit



It is not intended for continued human occupancy



It has poor ventilation



It has the potential for entrapment/engulfment



It has the potential for accumulating a dangerous atmosphere.

Before determining the proper procedure for confined space entry, a(n)____ must be performed.

Hazard review

Fall protection must be used when employees are in a walking or working surface that is _____ or more above a lower level and has an unprotected edge or side.

6 feet or site specific. Some sites are 4 feet.