  • Front
  • Back
AFFF
AQUEOUS FILM FORMING FOAM
AFFF AGENT DELIVERY SYST
FIGHTS LARGE CLASS "B" FIRE
HOW MANY AFFF STATIONS?
2

1-70-1-A (FWD PALLET)
1-300-1-Q (AFT DECON ST)
AFFF CONCENTRATE
6% AFFF
94% SEAWATER
CAPACITY OF EACH AFFF TANK
600 GALLONS
AFFF ON STBY
300 EACH TANK
5 GALLON BLUE BUCKETS
AFFF TOTAL GALLONS ONBOARD
1800
AFFF CONCENTRATE PUMP
DELIVERS AFFF CONCENTRATE FROM STORAGE TANK THROUGH THE VENTURI PROPORTIONER INTO THE DISTRIBUTION PIPING
BALANCING VALVE
CONTROLS FLOW OF AFFF CONCENTRATE,EITHER BACK TO THE TANK OR TO THE POWERCHECK VALVE.

AFFF PRESSURE IS EQUAL TO FIREMAIN PRESSURE ENSURING THE PROPER FOAM MIX
MAGNETIC SIGHT GLASS
DETERMINE THE LEVEL OF AFFF IN TANK
SEAWATER FLOW CONTROL VALVE (HYCHECK VALVE)
INCORPORATES A CHECK VALVE WHICH WILL PREVENT AFFF BEING FORCED BACK INTO THE FIREMAIN
SOLENOID OPERATED PILOT VALVES (SOPV's)
EACH AFFF HAS ONE MASTER

FWD AFFF HAS 3 SERVICE
AFT AFFF HAS HAS SIX SERVICE
MASTER SOPV
CONTROLS THE SEAWATER FLOW CONTROL VALVE AND AFFF FLOW CONTROL VALVE (HYCHECK VALAVE)
SERVICE SOPV ACTIVATION WILL CAUSE?
THE MASTER AND SERVICE SOPV's TO ACTIVATE ALLOWING THE AFFF TO FLOW TO THE MAIN LOOP AND TO WHICHEVER SERVICE-WAY (BILGE SPRINKLING OR VERTREP ST SPRINKLING) IS ACTIVATED
AFFF LOOP
CONTINUOUS LOOP THAT FUNCTIONS SIMILAR TO THE FIREMAIN LOOP
HALON 1301 SYSTEM
EXTINGUISHES FIRES THAT ARE BEYOND THE CAPABILITY OF FIRE EXTINGUISHING APPARATUS AND WHERE ABANDONMENT IS NECESSARY
HALON BOTTLES
STORES LIQUEFIED HALON PRESSURIZED WITH NITROGEN TO 600 PSI @ 70 DEGREES F
5LB CO2 ACTUATION BOTTLE
LOCATED AT EACH ACTIVATION POINT
USED TO ACTUATE THE SYSTEM
VENTILATION SHUTDOWN PRESSURE SWITCH
SHUTS DOWN VENTILATION SYSTEM PRIOR TO THE ACTIVATION OF HALON, PREVENTING HALON FROM BEING REMOVED BY EXHAUST VENTILATION.

ACTIVATED IMMEDIATELY AFTER 5LB CO2 IS ACTUATED
CPS AIR SWEEP PRESSURE SWITCH
CLOSES CPS AIR SWEEPS. ONLY AFFECTED SPACES ARE AUX 1, MER 1, MER 2
TIME DELAY DEVICE
PROVIDES A DELAY BETWEEN SYSTEM ACTIVATION AND ACTUAL HALON RELEASE, ALLOWING TIMEFOR VENTILATION SHUTDOWN
TYPES OF TIME DELAYS
30 SEC- UNMANNED
60 SEC- MANNED
60 SEC TIME DELAY FOR HALON
AUX 1, MER 1, MER 2, 3 GEN
30 SEC TIME DELAY FOR HALON
GTM/GTG MODULES AND FLAMMABLE LIQ ISSUE/STORAGE
TIME DELAY BYPASS SWITCH
IMMEDIATE DISCHARGE OF HALON BY BYPASSING THE TIME DELAY ASSEMBLY
WHO HAS AUTHORITY FOR RESERVE HALON IF PRIMARY IS BAD, ONLY AFTER THE CAUSE OF PRIMARY HALON BAD HAS BEEN CORRECTED?
DCA
CO2 EXTINGUISHER
PRIMARILY FOR EXTINGUISHING ELECTRICAL FIRES BUT CAN BE USED ON A AND B FIRES IF APPLIED BEFORE THE FIRE IS TOO LARGE
MAXIMUM EFFECTIVE RANGE OF CO2 EXTINGUISHER
4 TO 6 FT
WEIGHT OF CO2 IN PORTABLE BOTTLE
15 LBS
MAX TIME THE CO2 PORTABLE BOTTLE SPRAYS FOR?
40-45 SEC CONTINUOUS USE
WHAT CAN OCCUR BECAUSE CO2 HAS NO COOLING EFFECT ON THE FIRE?
REFLASH
SAFETY PRECAUTION WHEN DISCHARGING CO2 BOTTLE
KEEP CYLINDER IN CONTACT WITH THE DECK SO THERE IS NO STATIC BUILDUP CHARGE
WHAT IS REQ IN A SMALL SPACE AFTER CO2 HAS BEEN DISCHARGED?
SCBA
PKP EXTINGUISHER
CLASS B FIRES

LAST RESORT FOR C (HIGHLY CORROSIVE)
PKP ATTACKS WHAT?
CHAIN REACTION REQ TO SUSTAIN THE FIRE
PKP BOTTLES CARRIED ON BOARD
18 LB
27 LB
DISCHARGE TIME OF PKP BOTTLE
10 SECS-18LB
11 SECS- 27LB
EFFECTIVE RANGE OF PKP BOTTLES
19 FT- 18LB
21FT- 27LB
PORTABLE AFFF BOTTLES
PRIMARY USED FOR SMALL "B" FIRES, DEEP FRY FIRES
SMALL "A" FIRES, VAPOR SECURE A SMALL FUEL SPILL PREVENT FIRE AND USED DURING HOT WORK WATCH
AFFF EXTINGUISHER STORAGE
2-2 AND 1/2 GALLONS
AFFF EXTINGUISHER
PREMIXED SOLUTION OF AFFF CONCENTRATE AND FRESH WATER

100 PSI @ 70 DEGREES F
AFFF EXTINGUISHER WEIGHT
28 LBS
WHAT IS THE SOAK TIME FOR HALON PRIOR TO RE-ENTERING A MAIN SPACE?
15 MIN
WHAT ACTIVATES THE HALON SYSTEM?
CO2
WHAT FIXED FIRE FIGHTING EXTINGUISHING SYSTEM IS INSTALLED IN THE MAIN SPACES?
HALON
AT WHAT TEMPERTURE DOES HALON TURN TOXIC?
900 DEG. F
WHAT DOES EEBD STAND FOR?
EMERGENCY ESCAPE BREATHING DEVICE
HOW LONG WILL THE EEBD LAST?
10 MINS
ON THE EEBDS WHAT INDICATES A GOOD EEBD?
THE NEEDLE IS THE GREEN RANGE
WHAT TYPE OF FUEL DOES THE P-100 USE?
JP-5 OR DFM
COVERED BY FWD AFFF
AUX 1, MER 1,FWD VERTREP
WHERE ARE THE AFFF SEGREGATION VALVES
MESS DECKS AND MAIN MEDICAL, FRAME 220
SCBA
SELF CONTAINED BREATHING APPARATUS
COLLECTIVE PROTECTIVE SYSTEM
3 ZONES
WHAT IS THE HALON PROCESS?
5 LB CO2 ACTUATOR-PULL PIN AND PULL ON ACTUATOR LEVER. CO2 GOES FROM ACTUATOR TO 1ST PRESSURE SWITCH
WHAT HAPPENS AT 1ST PRESSURE SWITCH
VENTILATION SHUTS DOWN
CO2 TRAVEL TO 2ND PRESSURE SWITCH AND WHAT HAPPENS?
ALARMS ARE ACTIVATED
WHAT HAPPENS AT 3RD PRESSURE SWITCH
VENT DAMPNERS SHUT DOWN
WHAT HAPPENS AFTER3RD PRESSURE SWITCH AND VENT DAMPNER SHUTS DOWN
TIME DELAY-

30 SECS: UNMANNED
60 SECS: MANNED
WHAT HAPPENS AFTER TIME DELAY
CO2 GOES TO 4TH PRESSURE SWITCH
WHAT HAPPENS AT 4TH PRESSURE SWITCH?
DISCHARGE ALARM
RED LIGHT ON HALON
HALON DISCHARGED
HALON LIGHTS WHITE
PWR AVAILABLE
AMBER LIGHTS AMBER
HALON ACTIVATED
WHERE IS THE HALON STATION FOR #3 GTG
3 GEN
HALON PROTECTED SPACES
AUX 1
MER 1
MER 2
#3 GTG ROOM
FLAM LIQ STO
FLAM LIQ ISSUE
1A,1B,2A,2B GTM
1,2,3 GTG
CHEMICALLY INTERRUPTS THE COMBUSTION CHAIN REACTION
HALON 1301
EMERGENCY AFFF HOSE OUTLETS
1 AND 1/2" VALVES INSTALLED IN THE AFFF LOOP AT LEAST EVERY 50FT
SINGLE AGENT (AFFF) HOSE REEL
LOC ON DC DECK FOR ENG SPACE RE-ENTRY, FLIGHT DECK AND MACHINERY SPACES
GAS MASK
MCU-2P
WHAT DOES THE ACRONYM MOPP STAND FOR?
MISSION ORIENTATED PROTECTIVE POSTURE
HOW MANY MOPP LEVELS ARE THERE?
4
WHAT MOPP LEVEL HAS THE HIGHEST STATE OF READINESS?
4
HOW MANY DECON STATIONS ONBOARD?
2

BY SSES (PORT)
BY HELO HANGAR ENTRANCE (STRB)
HOW MANY ZONES DOES THE DECON STATION HAVE?
4
ZONES OF DECON STATION
OUTER CLOTHING UNDRESSING
INNER CLOTHING UNDRESSING
SHOWER
CONTAMINATION PURGE LOCK (CPL)
OUTER CLOTHING UNDRESSING
TAKE OFF ACPG, LEAVE ON MASK
INNER CLOTHING UNDRESSING
TAKE OFF UNDER GARMENTS, LEAVE ON MASK
SHOWER
LEAVE ON MASK, SHOWER, AFTER ICUA
CONTAMINATION PURGE LOCK
TAKE OFF MASK, MEDICAL EVAL
CHEMICAL WARFARE DIRECTIONAL DETECTOR (CWDD)
DETECTS AND IDs A NERVE AGENT CLOUD AT A DISTANCE USING PASSIVE INFRARED IMAGE SENSOR

CAN BE MOUNTED ON PORT AND STRB BRIDGE WINGS, NORMALLY STORED ON BRIDGE OR LOCKERS
IMPROVED POINT DETECTION SYST (IPDS)
SHIPBOARD SYST THAT OPERATES AN AUTOMATIC AND CONTINUOUS AIR SAMPLING DETECTOR

USED TO DETECT NERVE AND BLISTER AGENTS. SETS OFF ALARM ON THE BRIDGE AND DC WORKSTATION
M-256A1 CHEMICAL DETECTOR KIT
PORTABLE CAPABILITY FOR DETECTING OPERATIONAL CONCENTRATIONS (LIQ AND VAPOR) OF NERVE, BLISTER, AND BLOOD AGENTS
M-256A1 CHEMICAL DETECTOR KIT CONTENTS
12 SAMPLER DETECTORS, A BOOKLET OF M-8 PAPER, AND A PLASTIC OPERATIONAL INSTRUCTION CARD
SHELF LIFE OF M256A1
5 YEARS
SAMPLER DETECTORS
WILL DETECT NERVE (G AND V) BLISTER (L AND CX) AND BLOOD AGENTS (AC AND CK)
M-8 PAPER
MOUNTED IN DESIGNATED SPOTS OUTSIDE THE SKIN OF THE SHIP AND NEAR CPS VENTILATION DUCTS OR WATERTIGHT ACCESSES PRIOR TO CHEMICAL ATTACK
M-8 RED
BLISTER (H AND L)
M-8 YELLOW
NERVE (G SERIES)
M-8 GREEN
NERVE (V SERIES)
M-8 RESPONSE TIME
20 SECS
M-9 PAPER
DETECTS LIQUID CHEMICAL AGENTS BY COLOR CHANGE (RED)
FALSE POSITIVES FOR M-9
BLUE, YELLOW, GREEN, GRAY, OR BLACK SPOTS
M-9 RESPONSE TIME
10 SECS
MOPP LEVEL 0
PROTECTIVE MASKS FITTED
MOPP LEVEL 1
MED SUPPLIES ISSUED TO PERSONNEL
MOPP LEVEL 2
MASK CARRIED
SET UP DECON ST
PERFORM OP TEST PF CMWD
MOPP LEVEL 3
INSTALL CANISTERS ON MASKS
DON ACPG
SET GQ
ACTIVATE CMWD INTERMITTENTLY
CIRCLE W
MOPP LEVEL 4
DON MASK
HOOD UP ON ACPG
ACTIVATED CMWD CONT.
SHELF LIFE OF CANISTERS
5 YEARS
CANISTERS AFTER UNSEALING
60 DAYS UNSEALING IN NON-CHEM ENV
30 DAYS EXPOSURE
ATROPINE
NERVE AGENT ANTIDOTE
INJECT IN THIGH
UNSUP USE ONLY 3
2-PAM CHLORIDE
CONJUCT W/ ATROPINE TO COMBAT SYMPTOMS
ADMIN AFTER ATROPINE, 1 FOR 1
MAX 3 INJECT UNSUP
M-291 SKIN DECON KIT
DECONS LIQ AND CHEM AGENTS FROMEXPOSED SKIN AREAS BY PHY REMOVAL, ABSORPTION, AND NEUTRALIZATION
HOW MANY PACKETS IN M-291 DECON KIT
6
HOW MANY APPS FOR M-291 DECON KIT
6 PKTS, 3 COMPLETE SKIN APPS
SHELF LIFE OF M291 DECON KIT
5 YRS
HOW MANY TIMES CAN YOU WASH THE ACPG
6
HOW MANY DAYS CAN YOU USE ACPG AFTER UNSEALING
24 HRS CONTAM
45 UNCONTAM
120 DAYS HAVE ELAPSED SINCE OPENING ORIGINAL FACTORY SEALED PACKAGING
M-8 BOOKLET
25 PERFORATED SHEETS OR 50 SINGLE SHEETS
IS R134 A TOXIN
NO, NOT UNTIL HEATED PAST 750 DEG. F
HOW DOES R135 KILL YOU
KILLS BY SUFFOCATION FILLS THE LUNGS BY DISPLACEMENT
H2S
DANGEROUS, CAUSES DEATH
HANDLING REFRIGERANT
DISPLACES OXYGEN AND AT 250 DEGREES AND ABOVE IT BECOMES TOXIC GAS
STEEL SHORING LENGTHS
3 BY 5
6 BY 11
STEEL SHORING LOC
REP 5
DISBURSING
STEEL SHORING PRESSURE
3 BY 5-
COLLAPSED. 20000LBS
EXPANDED. 12000LBS

6 BY 11
COLLAP. 20000LBS
EXPAND. 6000LBS
SHORING TYPES
I, H,K
I SHORING
STRONGEST- HATCHES SCUTTLES
H SHORING
SMALLER COMPARTMENTS
K SHORING
LARGER COMPARTMENTS
JUBILEE PATCH
PRESSURE UP TO 100 PSI
EMERGENCY WATER ACTIVATED REPAIR PATCH (EWARP)
UP TO 150 PSI

NOT USED ON PW PIPES
SOFT PATCH
UP TO 150 PSI
BOX PATCH
METAL BOX FITTED W/ GASKET
BUCKET PATCH
BUCKET FITTED W/ GASKET
TYPES OF EDUCTORS
S TYPE AND PERIJET
HOW MANY EDUCTORS DOES MAIN DRAIN USE
3
BOX FAN RATED AT
DISPLACES 3200 CUBIC FT PER MIN OF AIR

115 VOLTS AC
RAM FAN RATED AT
2000 FPM
DISCHARGE RATE W/ P100
100 GPM @ 83 PSI
P100 PRIMARY USE
FF AND DEWATERING
WHERE DOES P100 CONNECT TO W/ HOSE
OVERBOARD DISCHARGE
USED FOR DE-FLOODING
P100
ELECTRIC SUBMERSIBLE PUMP
EDUCTORS
TYPES OF SCBA TANKS
30 MIN AND 45 MIN
WHAT IS SECONDARY DRAINAGE
SYSTEM THAT PROVIDES FOR DEWATERING OF CERTAIN SPACES THAT HAVE A FLOODING RISK
HOW MANY WAY TO CHARGE SCBA
QUICK CHARGE
STANDARD
ALPHA FIRE
ASH, DRY MAT, BOOKS

WATER
BRAVO FIRE
THICK BLACK SMOKE- GAS,FUEL

HALON, AFFF, PKP
CHARLIE FIRE
ELECTRICAL- BLUE SMOKE

CO2
DELTA FIRE
METALS

WATER, JETTISON
1ST STAGE REGULATOR
REDUCES PRESSURE TO 100 PSI
2ND STAGE REGULATOR
REDUCES AIR TO BREATHABLE AIR
NFTI
NAVY FIREFIGHTING THERMAL IMAGER
SCBA REFILLING STATIONS
REP 5 AND 3
CO2 BOTTLE FIRES?
A AND C
PKP BOTTLE TYPES
18 AND 27 LB
PKP BOTTLE FIRE TYPE
B
LAST RESORT- C
SCBA STORED AT WHAT?
4500 PSI
HOW MANY FIRE PUMPS? RATED AT? LOC?
6 @ 1000GPM @ 150 PSI

FWD VCHT
AUX 1
MER 1
MER 2
SHAFT ALLEY
3 GEN
WHAT DOES EVERY FIRE PUMP HAVE
SEA CHEST

FP #6 HAS 2 (3 GEN)
WHAT TYPE OF FIRE MAIN?
8" VERTICAL OFFSET LOOP
WHAT VCHT HAS A FP
FWD