Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
124 Cards in this Set
- Front
- Back
1. WHAT IS THE PURPOSE OF THE LIST CONTROL SYSTEM?
|
TO KEEP AN EVEN KEEL DURING FLIGHT OPERATIONS
|
|
2. WHAT INSTRUMENT IS USED TO MEASURE THE SHIPS LIST?
|
CLINOMETER
|
|
3. WHERE ARE THEY LOCATED?
|
DCC, BRIDGE, FLIGHT DECK CONTROL, 3MMR, REPAIR 3, ENGINEERS OFFICE, ENGINEERS STATEROOM
|
|
4. HOW IS THE LIST MEASURED?
|
IN DEGREES FROM PORT TO STBD
|
|
5. HOW MANY LIST CONTROL TANKS ARE THERE?
|
12
|
|
6. HOW MANY MODE OF CHT ARE THERE?
|
3
|
|
7. WHAT ARE THE MODES OF CHT?
|
INPORT, TRANSIT AND OUT TO SEA
|
|
8. HOW MANY CHT TANKS ARE THERE?
|
8
|
|
9. HOW MANY CHT RISERS ARE THERE?
|
4
|
|
10. WHERE ARE THEY LOCATED?
|
MAIN DECK SMOKE SPONSON, S-8 SPONSON, STBD BOAT DAVITT, DECK HOUSE ONE
|
|
11. HOW FAR MUST YOU BE TO PUMP CHT OVER THE SIDE?
|
3NM
|
|
2. WHAT DOES HCFF STAND FOR?
|
HIGH CAPICITY FOG FOAM
|
|
13. HOW MANY HCFFS ARE ONBOARD JFK?
|
17
|
|
14. HOW MANY GALLONS OF AFFF CONCENTRATE CAN EACH STATION HOLD?
|
600
|
|
15. HOW MANY AFFF X-FER STATIONS ARE ON BOARD JFK?
|
2
|
|
16. WHAT IS THE CAPACITY OF CONCENTRATE EACH X-FER STATION HOLDS?
|
3626
|
|
17. WHAT IS THE PERCENT OF AFFF TO WATER?
|
6% AFFF TO 94% WATER
|
|
18. HOW LONG DOES A 5GALLON CAN OF AFFF LAST?
|
60 SEC.
|
|
19. WHAT IS THE AFFF SOUND POWERED PHONE CIRCUIT?
|
X-50-J
|
|
20. WHAT AREAS DO THE HCFF SERVE?
|
MAIN SPACES, FLIGHT DECK, HANGAR BAYS, PUMP ROOMS, FWD AND AFT AIR START
|
|
21. WHAT ARE HCFFS USED FOR?
|
TO PROVIDE AFFF TO THE SPACES WITH MAJOR CLASS BRAVO HAZARDS
|
|
22. WHAT DECK IS ALSO CALLED THE DC DECK?
|
2ND
|
|
23. WHAT IS THE LENGTH OF THE RE-ENTER HOSE REELS FOR THE MAIN SPACES?
|
125 FT
|
|
24. WHAT DOES SOPV STAND FOR?
|
SILONOID OPERATED PILOT VALVE
|
|
25. HOW LONG DOES A 15LB CO2 BOTTLE LAST UNDER CONTINEOUS USE?
|
45 SEC.
|
|
26. WHAT IS THE RANGE OF A 15LB CO2 BOTTLE?
|
4-6 FEET FROM THE TIP OF THE HORN
|
|
27. WHAT DOCUMENT IS USED IN COMBATING MAIN MACHINERY ROOM FIRES?
|
MAIN SPACE FIRE DOCTRINE
|
|
28. WHERE ARE THE MAIN SPACE FIRE DOCTRINES LOCATED?
|
DCC, FIRE MARSHALL OFFICE, REPAIR LOCKERS, MSC
|
|
29. WHAT ARE THE FRAMES THAT MAKE UP THE BOX?
|
88-172
|
|
30. WHAT ARE THE MAIN SPACE REPAIR LOCKERS?
|
4/5F AND 4/5A
|
|
31. WHATS HCFFS PROVIDE FOAM TO THE MAIN SPACES?
|
11-May
|
|
32. WHAT FIXED FIRE FIGHTING EXSTINGUSHING SYSTEM IS INSTALLED IN THE MAIN SPACES?
|
HALON
|
|
33. WHERE WOULD HALON ALARMS BE RECEIVED?
|
DCC AND ON STATION
|
|
34. WHAT ACTIVATES THE HALON SYSTEM?
|
CO2
|
|
35. WHAT TYPE OF HALON DO WE HAVE ONBOARD?
|
HALON 1301
|
|
36. HALON IS STORED IN WHAT FORM?
|
LIQUID
|
|
37. WHAT IS THE SOAK TIME FOR HALON PRIOR TO RE-ENTERING A MAIN SPACE?
|
15 MIN
|
|
38. HOW LONG IS THE TIME DELAY FOR HALON/CO2 FIXED FLOODING SYSTEMS?
|
30 SECONDS FOR UNMANNED SPACES AND 60 SECONDS FOR MANNED SPACES
|
|
39. AT WHAT TEMPERTURE DOES HALON TURN TOXIC?
|
900 DEG. F
|
|
40. WHAT GAS IS USED TO PRESSURIZE THE HALON CYLINDER?
|
NITROGEN
|
|
41. WHAT IS THE PRECENTAGE OF HALON DISCHARGED INTO A MAIN SPACE?
|
7%
|
|
42. WHERE ELSE ON BOARD, BESIDES MAIN SPACES CAN HALON BE FOUND?
|
PUMP ROOMS, CAPTAINS IN-PORT CABIN, FLAG MESS, DIESEL GENERATOR ROOMS, HLU LOCKERS
|
|
43. WHERE CAN HALON BE ACTUATED?
|
ENTRANCE OF THE SPACE AND IN THE EOS
|
|
44. HOW MANY REPAIR LOCKERS ARE ON-BOARD JFK?
|
10
|
|
45. WHAT REPAIR LOCKER IS DESINATED AS THE FLIGHT DECK LOCKER?
|
7B
|
|
46. WHAT 3 LOCKERS ARE LOCATED IN THE HANGAR BAY?
|
1A, 1B, 1F
|
|
47. HOW MANY REPAIR LOCKERS ARE ON THE 2ND DECK?
|
4
|
|
48. WHICH LOCKER IS DESINATED AS SECONDARY DCC?
|
REPAIR 3
|
|
49. WHERE DOES THE “ENGINEERING OFFICER OF THE WATCH” GO WHEN DCC HAS TO BE EVACUATED?
|
3 MAIN MACHINERY ROOM
|
|
50. WHAT TYPE OF OBA DO WE HAVE ONBOARD JFK?
|
A-4
|
|
51. WHAT COLOR IS THE OBA CANISTER?
|
GREEN
|
|
52. HOW LONG DOES IT LAST?
|
30-45 MIN
|
|
53. HOW DO YOU SET THE OBA TIMER?
|
60 BACK TO 30 TO GET A FULL WIND ON THE SPRING
|
|
54. WHAT DOES EEBD STAND FOR?
|
EMERGENCY ESCAPE BREATHING DEVICE
|
|
55. HOW LONG WILL THE EEBD LAST?
|
10 MIN
|
|
56. ON THE NEW EEBDS WHAT INDICATES A GOOD EEBD?
|
THE NEEDLE IS THE GREEN RANGE
|
|
57. WHAT DOES PHARS MEAN?
|
PORTABLE HYDROLIC ACCESS AND RESCUE SYSTEM
|
|
58. WHAT IS THE PURPOSE OF THE PHARS?
|
TO PROVIDE ACCESS THROUGH OR INTO SPACES, BY CUTTING, SLITTING, PIERCING, LIFTING AND PULLING, WHERE RESCUE OR OVERHAUL IS NEEDED.
|
|
59. WHAT IS THE STANDARD LENGTH OF A FIRE FIGHTING HOSE?
|
50FT
|
|
60. WHAT IS THE MINIMUM MANNING FOR A 1 ½ FIRE FIGHTING HOSE?
|
5-Mar
|
|
61. WHAT IS THE MINIMUM MANNING FOR A 2 ½ FIRE FIGHTING HOSE?
|
7-May
|
|
62. WHAT IS THE OUTPUT FOR VARI-NOZZLES WITHIN THE SKIN OF THE SHIP?
|
95 GPM
|
|
63. WHAT IS THE OUTPUT FOR VARI-NOZZLES OUTSIDE THE SKIN OF THE SHIP?
|
125 GPM
|
|
64. HOW MANY P-100 PUMPS ARE ONBOARD JFK?
|
2
|
|
65. WHERE ARE THE P-100'S LOCATED?
|
FWD AIMD TUNNEL AND MAIN DECK STBD SIDE BELOW THE MOTER WHALEBOAT
|
|
66. WHAT IS THE RATED GALLONS PER MIN?
|
100
|
|
67. HOW IS THE P-100 COOLED WHILE IN OPERATION?
|
AIR COOLED
|
|
68. WHAT TYPE OF FUEL DOES THE P-100 USE?
|
JP-5 OR DFM
|
|
69. WHAT IS THE SUCTION LIFT OF THE P-100 PUMP?
|
16-20 FEET
|
|
70. WHAT POWERS THE RAMFAN?
|
FIREMAIN
|
|
71. WHY SHOULD THE RAMFAN BEGROUNDED?
|
TO PREVENT THE BUILD UP OF STATIC ELECTRICITY
|
|
72. HOW MUCH AIR WILL THE RAMFAN MOVE?
|
1750 CFM @ 125 PSI
|
|
73. WHAT IS THE POWER SOURCE OF THE BOX FAN?
|
115 VAC
|
|
74. HOW MANY CUBIC FEET OF AIR WILL THE BOX FAN MOVE?
|
3200
|
|
75. HOW MANY JETS ARE IN THE PERI-JET EDUCTOR?
|
6
|
|
76. WHAT SIZE IS THE DISCHARGE HOSE ON A PERI-JET EDUCTOR?
|
4IN
|
|
77. WHAT SIZE DISCHARGE HOSE WOULD YOU CONNECT TO THE 1 ½ PORTABLE EDUCTOR?
|
2 ½ IN
|
|
78. WHO IS THE ONLY PERSON THAT CAN ENERGIZE THE ELECTRICAL SUBMERSIBLE PUMP?
|
REPAIR PARTY ELECTRICIAN
|
|
79. HOW MANY GALLONS OF LIQUID WILL THE ELECTRICAL SUBMERSIBLE PUMP DELIVER?
|
180-200 GPM @ 50FT STATIC HEAD, 120-140 GPM @ 70FT STATIC HEAD
|
|
80. WHY SHOULD A STRAINER BE USED WITH THE ELECTRICAL SUBMERSIBLE PUMP?
|
TO KEEP DEBRIS FROM ENTERING THE PUMP
|
|
81. WHAT DOES STATIC HEAD MEAN?
|
THE VERTICAL DISTANCE THAT THE PUMP HAS TO OVERCOME
|
|
82. WHAT IS THE POWER SOURCE FOR THE SUBMERSIBLE PUMP?
|
440 VOLTS
|
|
83. WHEN USING SUBMERSIBLE PUMPS IN TANDEM, WHICH PUMP SHOULD BE STARTED FIRST?
|
THE ONE IN THE WATER
|
|
84. WHAT ARE 4 TYPES OF PIPE PATCHES?
|
EWARP, SOFT, JUBILEE, BANDING
|
|
85. WHAT IS THE PSI FOR THE SOFT PATCH?
|
150PSI
|
|
86. WHAT DOES THE ACRONYM EWARP STAND FOR?
|
EMERGENCY WATER- ACTIVATED REPAIR PATCH
|
|
87. NAME THREE TYPES OF SHORING?
|
I, H, AND K
|
|
88. WHICH TYPE OF SHORING IS THE STRONGEST?
|
I
|
|
89. WHAT IS THE MAXIMUM LENGTH OF A WOODEN SHORE?
|
30 TIMES THE MINIMUM BUTT THICKNESS
|
|
90. WHAT ARE THE LENGHTS OF METAL SHORES?
|
3-5FT AND 6-11FT
|
|
91. WHAT TYPE OF FIREMAIN DOES JFK HAVE?
|
COMPSITE LOOP
|
|
92. HAW MANY FIRE PUMPS ARE ONBOARD JFK?
|
21
|
|
93. HOW MANY ARE STEAM?
|
4
|
|
94. WHAT IS THE OUTPUT OF A STEAM FIRE PUMP?
|
2000 GPM
|
|
95. WHAT IS THE OUTPUT FOR ELECTRIC FIRE PUMPS?
|
1000 GPM
|
|
96. WHAT DOES APC STAND FOR?
|
AQUEOUS POTASSSIUM CARBONATE
|
|
97. WHERE CAN THE APC SYSTEM BE FOUND?
|
IN THE GALLEY
|
|
98. WHAT IS THE APC SYSTEM USED FOR?
|
PUT OUT GREASE FIRES IN THE DEEP FAT FRYERS
|
|
99. AT WHAT TEMPERTURE WILL THE FUSIBLE LINK MELT AND ACTIVATE THE APC SYSTEM?
|
360 DEG. F
|
|
100. WHAT DOES NFTI STAND FOR?
|
NAVAL FIREFIGHTING THERMAL IMAGER
|
|
101. HOW MANY MODES DOES THE NFTI HAVE?
|
2
|
|
102. WHAT ARE THE MODES FOR THE NFTI?
|
PAN AND CHOP
|
|
103. HOW MANY BATTERIES AND WHAT ARE THE SIZES FOR THE NFTI?
|
10 “AA”
|
|
104. HOW LONG WILLS THE NFTI LAST WITH ALIKALINE BATTERIES?
|
60-90 MIN
|
|
105. HOW MANY LED LIGHTS WILL YOU GET WITH NEW BATTERIES?
|
5
|
|
106. WHATS HAPPENS TO THE NFTI WHEN PEERING THROUGH GLASS?
|
IT WILL WHITE-OUT
|
|
107. AT WHAT INTERNAL TEMPERTURE WILL THE NFTI WHITEOUT?
|
140 DEG F.
|
|
108. WHAT REFERENCE IS USED FOR SHIPBOARD FIREFIGHTING?
|
NSTM 555
|
|
109. WHAT TYPE OF GAS MASK DO WE HAVE?
|
MCU/2P
|
|
110. WHAT TYPE OF CANISTER IS USED WITH THE MCU/2P GAS MASK?
|
C-2
|
|
111. HOW LONG WILL THE C-2 CANISTER LAST IN A CONTAMINATED ENVIROMENT?
|
30 DAYS OR ONE BLOOD AGENT ATTACK
|
|
112. WHAT DO NATO THREADS MEAN?
|
THE GAS MASK CANISTER CAN BE USED WITH ANY OTHER COUNTRIES GAS MASK
|
|
113. IN CBR TERMS WHAT DOES CPO STAND FOR?
|
CHEMICAL PROTECTIVE OVERGARMENT
|
|
114. HOW LONG WILL THE CHEMICAL PROTECTIVE OVERGARMENT LAST IN A NON-CONTAMINATED ENVIROMENT?
|
100 HOURS CUMULATIVE WEAR TIME OR 30 DAYS WHICH EVER COMES FIRST. WHAT ABOUT A CONTAMINATED ENVIROMENT?
|
|
115. HOW MANY CCA/DECON STATIONS ARE ON BOARD JFK?
|
4
|
|
116. WHAT DOES THE ACRONYM MOPP STANDFOR?
|
MISSION ORIENTATED PROTECTIVE POSTURE
|
|
117. HOW MANY MOPP LEVELS ARE THERE?
|
4
|
|
118. WHAT MOPP LEVEL HAS THE HIGHEST STATE OF READINESS?
|
MOPP LEVEL 4
|
|
119. THERE ARE THREE TYPES OF RADIACS THAT WE HAVE ON BOARD JFK, NAME TWO.
|
AN/PDR-65, AN/PDR-43, AND AN/PDR-27
|
|
120. WHERE IS THE AN/PDR-65 LOCATED?
|
THE BRIDGE AND DCC
|
|
121. WHERE IS THE PROBE LOCATED?
|
ON THE MAST
|
|
122. WHAT ARE THE NUCLEAR TYPES AND CHARACTERISTICS
|
A. HIGH ALTITUDE BURST [ABOVE 100,000 FT] EFFECT- ELECTROMAGNIC PULSE; B. AIR BURST [LESS THAN 100,000 FT, FIREBALL DOES NOT TOUCH THE SURFACE] EFFECT- INITIAL RADIATION; C. SURFACE BURST [FIREBALL TOUCHES THE SURFACE] EFFECTS- AIR BLAST; D. SUB-SURFACE BURST (UNDERWATER) [FIREBALL VENTS TO THE WATERS SURFACE] EFFECT- UNDERWATER SHOCKWAVE (& OR) BASE SURGE
|
|
123. HOW MANY CCA/DECON STATIONS ARE THERE ON BOARD JFK?
|
4
|
|
124. WHAT IS A CCA?
|
CONTAMINATION CONTROL AREA
|