  • Front
  • Back

Boiler water legs:


1) Surround the furnace entirely


2) Support the boiler on concrete piers


3) Increase the heating surface


4) Make waterside maintenance easier


5) Make water treatment less critical

3) Increase the heating surface

The steam and water spaces of a cast iron sectional boiler are connected by:


1) Push nipples


2) Tie nipples


3) Hydraulic jacks


4) Steel studs


5) Tie rods

1) Push nipples

A cast iron boiler disadvantage is:


1) It is subject to corrosion


2) Its high ductility


3) Its pressure limitations


4) Its difficult assembly


5) Its extremely high cost

3) Its pressure limitations

The steam and water spaces of a cast iron sectional boiler are held together by:


1) Push nipples


2) Steel studs


3) Cast iron pipes


4) Push studs


5) Tie rods

5) Tie rods

Heating boilers attain maximum efficiency only when they are operated:


1) Intermittently at half load


2) Continuously at full load


3) Continuously at half load


4) Continuously at 75% of the load


5) Intermittently at 90% of the load

2) Continuously at full load

Modular cast iron boiler water flow is:


1) Intermittent, occurring only while the unit is firing


2) Always vertically upwards


3) Connected in series


4) Continuous through all modules


5) Done without the use of headers or manifolds

4) Continuous through all modules

Most low capacity cast iron boilers:


1) Can withstand higher pressures


2) Cannot be site assembled


3) Are factory assembled as packaged units


4) Require special foundations


5) Will pass through standard size doorways

5) Will pass through standard size doorways

To prevent flue gases from escaping in a cast iron sectional boiler, the spaces between the sections are sealed with high temperature:


1) Putty


2) Plastic insulation


3) Asbestos rope


4) Foam insulation


5) Silicon chalking

3) Asbestos rope

In a vertical sectional boiler, the sections are placed:


1) 45° to each other


2) Side by side


3) One above the other


4) 90° to each other


5) 180° to each other

2) Side by side

A modem is a device that:


1) Stores bits of information into groups of eight called bytes


2) Allows the CPU to perform more than one task at a time


3) Converts analog signals to digital


4) Converts digital signals to analog signals


5) Allows the computer to communicate over analog lines

5) Allows the computer to communicate over analog lines