• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/13

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

13 Cards in this Set

  • Front
  • Back

Relative to boilers and pressure vessels, a code that has not been adopted by all the provinces is:


A) CSA B52


B) ANSI B.31.5


C) NFPA


D) ASME I through IX


E) CSA B51


C) NFPA

A body which was formed in 1919 for the promotion of safety and uniformity in the construction, installation and inspection of boilers and pressure vessels was the:


A) ASME


B) CSA


C) Underwriter Laboratories Canada


D) NFPA


E) National Board of Boiler and Pressure Vessel Inspectors


E) National Board of Boiler and Pressure Vessel Inspectors

The code that regulates mechanical refrigeration is the:


A) ASME Section IV


B) CSA B-52


C) ASME Section I


D) CSA B-51


E) ASME Section VII


B) CSA B-52

The first Canadian province to enact boiler and pressure vessel legislation was:


A) Ontario


B) Alberta


C) Newfoundland


D) Manitoba


E) Quebec


E) Quebec

Heating boiler means a boiler:


A) Where water is heated to a pressure exceeding 1 100 kPa and a temperature of 121ºC


B) Which does not require a sight glass


C) Where steam is produced at a pressure greater than 103 kPa


D) Where steam is produced at a pressure of 103 kPa or less


E) In which only hot water is produced


D) Where steam is produced at a pressure of 103 kPa or less

Once you have taken over a shift in a high pressure boiler plant, you may leave the boiler unattended for:


A) No period of time


B) The time specified in the union agreement


C) 4 hours


D) 40 minutes


E) 15 minute intervals


A) No period of time

When calculations are made with respect to the application of the Boilers Act, 10 kilowatts is equal to:


A) 1 m² of heating surface


B) 0.5 m² of heating surface


C) 2 m² of heating surface


D) 5 m² of heating surface


E) 10 m² of heating surface


A) 1 m² of heating surface

After an initial inspection of a boiler or pressure vessel, an Alberta identification number preceded by the letter "A" in a/an _____ shall be stamped on the boiler or pressure vessel.


A) Circle


B) Rectangle


C) Square


D) Octagon


E) Hexagon


A) Circle

A fitting, as defined in the "Act", means a:


A) Fan


B) Pump


C) Stack


D) Gauge glass


E) Feedwater regulator


D) Gauge glass

The Act and Regulations do not apply to a:


A) Power plant having a boiler rating of 10 kW or less


B) Heating plant having a rating of 25 kW or more


C) Heating plant having a boiler rating of 20 kW or more


D) Heating plant having a boiler rating of 30 kW or less


E) Power plant having a boiler rating of 20 kW or less


A) Power plant having a boiler rating of 10 kW or less

The Province of Alberta currently has various certificates of competency relative to Power Engineering and Boiler Operation, the number being:


A) 12


B) 6


C) 4


D) 8


E) 10

E) 10

A Fourth Class Engineer's Certificate of Competency qualifies the holder to take charge of a Power Plant not exceeding:


A) 1 000 kW


B) 500 kW


C) 2 500 kW


D) 5 000 kW


E) 100 kW

A) 1 000 kW

Definitions such as shift engineer, chief engineer and fireman are found in:


A) Alberta's Safety Codes Act


B) Alberta Engineers' Regulations


C) Municipal codes


D) CSA B-51


E) ASME Code Section VIII


B) Alberta Engineers' Regulations